Automatic Changeover Switch Transfer Switch ATS 100A 200A 400A 630A 1000A 1600A Dual Power

Modelo NÃO.
ATS 100A

Marca comercial
GWIEC

Origem
Wenzhou, Zhejiang, China

Código HS
8536500000

Descrição

Product Information:

Automatic Transfer Switch ATS 250A 4 Pole Changeover Switch Single PhaseAutomatic Transfer Switch ATS 250A 4 Pole Changeover Switch Single Phase

Product parametre:

Product Brand:

GWIEC

Nome do produto:

Automatic transfer switch

Product Type:

ATS-100(100UMA)

Rated frequency (fr):

50 Hz-60Hz

Standards:

IEC60947

Insulated Voltage Ui:

750V

Mode of operation:

Automatic/manual

Pole:

3P/4P

Conversion time:

≤2s Working voltage: AC220V

Inscrição:

ATS series Automatic transfer switch mainly used for distribution or electromotor network, which under voltage 400V, rated voltage DC 220V, Rated current 63A-3200A.
Main power and standby power or mutual standby power change over system or city power and generator group overload switch-over. At the same time, it can operated under un-frequency on and off circuit act as disconnector.
Widely used at the field of important power supply site, which transport, distribution power supply system and automatization system. For fire protection,hospital,bank,building,etc, where doesn’t allow power off.

Especificação:

Conventional thermal current(Ith) 100UMA 250UMA 630UMA 1000UMA 1600UMA

Rated Current(In)

20UMA 40UMA 60UMA 80UMA 100UMA 125UMA 160UMA 250UMA 400UMA 630UMA 800UMA 1000UMA 1250UMA 1600UMA
Rated insulation voltage(Ui) 750V 1000V
Rated concussion withstand voltage(Uimp) 8KV 12KV
Rated working voltage(Ue) AC440V
Rated working current(Ie) AC-31A 20 40 63 80 100 125 160 250 400 630 800 1000 1250 1600
AC-35A 20 40 63 80 100 125 160 250 400 630 800 1000 1250 1600
AC-33A 20 40 63 80 100 125 160 250 400 630 800 1000 1250 1600
Rated connection capacity 10le
Rated breaking capacity 8le
Rated limited short-circuit current(ls) 50kA 70kA 100kA 120kA
Rated short-time withstand current(ls) 7kA 9kA 13kA 26kA 50kA
Transfer I-II or II-I 0.45é 0.6é 1.2é
Control Power voltage DC24V. 48V. 110V. AC220V
Electrical consumption
Rated frequency Start 300C 325C 355C 400C 440C
Normal 55C 62C 74C 90C 98C
Peso(kg) 4 pole 7.0 7.2 7.2 7.2 7.5 7.5 8.8 9.0 16.5 17 32 36 40

43

Outline and mounting dimension: