Description
Natural gas generator sets include biogas-fueled reciprocating internal combustion engines, alternators, electrical parts, control devices, cooling systems, lubrication systems, exhaust systems, fuel systems, and auxiliary equipment. Except for the exhaust pipe and silencer of the exhaust system, they are mounted on a steel chassis. The generator set is a fixed permanent installed generator set. The steel underframe is mounted to the concrete foundation.
2. Main structure of the biogas engine
Series 190 closed-loop electronic control gas engine is developed by our company with the cooperation of American WOODWARD. It is the engine that mixes air and fuel before turbocharger. The power performance, fuel economy and reliability of this gas engine reach world advanced level by adopting world advanced outer mixing mode, electronic control technology and lean-burnt strategy.
The gas fuel of this engine series can be natural gas, biogas, syngas, coal mine gas, and etc. In order to meet the requirements of different customers, this gas engine can be packaged into generating set or other power take-off.
3. Alternator
The brushless constant-voltage synchronous alternators are of the self-excited type with an electronic voltage regulator integrated in the excitation system. They are used as main or standby units in land based power installations and for ships’ electrical systems and can be driven by internal combustion engines or gas, steam and water turbines and electric motors.
Structure:
The alternator comprises the main machine exciter and excitation system. The main machine is of revolving magnetic field with cylindrical rotor and damper winding. The exciter is revolving armature machine. The exciter power is supplied to the rotor of the main machine via rotating rectifiers.
4. Genset control panel
Dedicated gas genset control panel is in the shape of cabinet. With controller, various indicating instruments, regulating buttons, protection indicators, emergency shut-down button installing inside to monitor the working status of the genset. Speed regulation is executed by the electronic governor and the fine regulation can also can be done by the buttons on the control panel. The voltage of the genset is automatic through the buttons on the control panel.
Working power resource of the cabinet is DC24V (2 batteries). There is charger inside the cabinet.
5. Parameter table
JDEC 1000kw biogas generator set data | |
Genset model | 1000GF-N |
Engine model | H16V190ZLDZ |
Alternator model | IFC6 Series or equivalent |
Control panel | GPL 1000 |
Rated voltage | 10.5kV |
Power factor | 0.8 (lagging) |
Rated frequency | 50/60Hz |
Rated speed | 1000/1200rpm |
Starting method | 24V DC start |
Voltage regulating method | AVR (Automatic voltage regulation) |
Speed governing method | Electronic governor |
Ignition system | Digital ignition system |
Cooling mehtod | Forced water cooling with multi-fans radiator |
Coupling method | Flexible coupling |
Reference dimension | 9205x2350x2610mm (the drawing will be presented after signing of contract) |
Reference weight | 24500kg |
Biogas engine data | |
Model | H16V190ZLDZ |
Engine type | Four strokes, spark plug ignited, turbocharged and water cooled |
Cylinder arrangement | V type, 60° |
Bore | 190mm |
Stroke | 210mm |
Displacement | 95.27L |
Rated speed | 1000rpm |
Idle speed | 700rpm |
Lube oil consumption | ≤0.8g/kwh |
Exhaust temperature (before turbo) | ≤650ºC |
Jacket water outlet temperature | ≤85ºC |
Lube oil temperature in oil pan | ≤90ºC |
Oil pressure in main oil passage | 400-800kpa |
Oil pressure in turbocharger | 200-400kpa |
Steady speed regulation | 0-5% adjustable |
Cooling method | Forced water cooling, multi-fans radiator |
Lubricating method | Pressure and splashing lubricating |
Ignition method | Spark plug ignition |
Starting method | 24V DC start |
Rotating direction | Counterclockwise (flywheel view) |
Output method | Flywheel output |
Alternator data | |
Model | IFC6 series or equivalent |
Rated capacity | 1250kva |
Rated voltage | 10.5kV |
Rated frequency | 50Hz |
Power factor | 0.8 (lagging) |
Rated speed | 1000rpm |
Protection class | IP23 |
Insulation class | H |
Phases and connection | 3 phases and 4 wires |
Exciting method | Brushless |
Voltage regulating method | AVR automation |
Steady state voltage regulation ratio | ≤±2.5% |
Transient voltage regulation ratio | ≤+20% (-15%) |
Voltage settling time | ≤ 1.5s |
Voltage fluctuation ratio | ≤1% |
Steady state frequency regulation ratio | 0-5% |