Description
Production Line:
Description:
1. Preformed guy grips Armor Rod are designed to protect the conductor by educing bending, compression, and abrasion at the support point.
2. Preformed guy grips Armor Rod are recommended as protection for spans greater Than 300 ft. (91m).
3. Preformed Armor Rod are designed for use with ADSS, OPGW and ACAR conductors As well as Alumoweld and steel ground wire.
4. The material of Preformed Armor Rod is aluminum alloy or aluminum Covered steel wire.
5. Preformed Armor Rod sets are manufactured with right-hand lay as standard
Detailed Description:
Product Name: OPGW preformed dead-ends
Model: ONZ
The preformed dead-ends can protect and provide cushioning to the OPGW cables. The special design of helical rods makes ensure that preformed dead-ends can not cause undue stress to the OPGW cables, so that the normal lifetime of cable system is ensured.
RTS (Rated Tensile Strength): 40KN ~160KN
Structure and Raw Material:
Anchor Shackle: Hot dipped galvanized steel. Anchor Shackle is connected with fastener clamp on tensile pole (or tower).
Extension Link: Hot dipped galvanized steel. Parallel Plate is connected Anchor Shackle and Clevis Thimble.
Clevis Thimble: Hot galvanized cast steel. Clevis Thimble is plugged in bend of Outer Reinforcing Rods for protection and connected.
Inner reinforcing Rods: Inner reinforcing rods are made of aluminium clad steel rods. With a layer of particle emery inside, Inner Protection Rods can increase friction and decrease side pressure to cables. Rods are made into four subsets which can reduce misalignment errors and speeds installation. The ends are bent outward to avoid stress to OPGW cables.
Outer dead-end Rods: Rods are made into one subset with a layer of firm emery inside, in order to increase gripping power of Outer Reinforcing Rods while decreasing side pressure. Sets are color marked to reduce misalignment errors and to speed installation
Ground clamp: Aluminum alloy
Application Guide:
1. The preformed dead-ends are designed to connect Continue pole(or tower) and Terminal pole(tower), tensile pole(tower). The special specification: One unit per Terminal pole(tower), two units per tensile pole(tower) and two units per Continue pole(tower).
2. Select the Specification Model corresponding to the cable diameter range, Rated Tensile Strength.
3. Ground Clamps are sold together with Tension Sets, and prohibited directly installing on the Outer Reinforcing Rods and Inner Protection Rods.
Technical Specifications:
Model | CableDia(mm) | Inner Armor Rod (mm) | Outer Armor Rod (mm) | Extension Link | Anchor shackle |
OXZ-050-9.5 | 8.3-9.5 | 1500 | 1100 | PH-7 | U-7 |
OXZ- 050-10.2 | 9.6-10.2 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-11.5 | 10.3-11.5 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-12.4 | 11.6-12.4 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-13.4 | 12.5-13.4 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-14.4 | 13.5-14.4 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-15.4 | 14.5-15.4 | 1500 | 1100 | PH-7 | U-7 |
OXZ-050-16.4 | 15.5-16.4 | 1500 | 1100 | PH-7 | U-7 |