Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner

Modelnr.
ZTVC

Cooling/Heating
Cooling/Heating

Stroombron
Elektrisch

Power Type
AC

Voorwaarde
Nieuw

Eer
3.32-4.72

Cop
3.56-5.5

Comperssors
DC Inverter

Outdoor Unit Aiflrow Rate dB(A)
45-63

Koelmiddel
R410A

Cooling Capacity
8kw-61.5kw

Heating Capacity
9kw-69kw

Operating Temp. Range(Cooling/Heating)
-5-55/-20-30

Max.Esp
85

Voeding
208-230V, 220-240V, 380-415V

Transportpakket
Pallet, PE Bag, Karton, Corner Protector

Specificatie
Net Weight: 240 kg; Gross Weight: 255kg;

Handelsmerk
ZERO

Oorsprong
China

Productiecapaciteit
30000 Set/Month

Beschrijving

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air ConditionerZERO VRF is a powerful system for your next HVAC project if you are looking for cost effective solutions.
We offer one stop solution includes VRF drawing design, model selection, instalation material calculation, start up
guidance etc, equipments, installation material and other parts will be loaded all together in the same containers
directly ship to your job site, we make your VRF projects never been so easy.

WHY CHOOSE US

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner

1.Experience
More than 15 years of overseas HVAC project experience,with deep understanding of global markets.

2.Professional design
Our professional design team are ready to provide you a AC plan drawing based on your architecture blueprint, we will advise the most suitable solution.

3.Professional selection
We can select the most suitable model for your project according to the drawings.

4.One-stop solution
The necessary installation material and other parts can be collected and loaded them all together directly ship to your job site, which is truly one-stop solution.

5.Technical support
Professional technical support, worry-free after sales.

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner1.Project Drawing, building layout, equipment BOQ.
2.Project name: building name or building type, such as xxx office project, residential house project etc.
3.Expected shipping date of this project.
4.Project type: tender or self-owned.

Products Line

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner 8/10/12PK 14/16HP 18/20HP 22HP 24HP 26/28/30/32HP

13 BASIC MODULES (380V-3Ph-50/60Hz)

PK 8
10
12
14 16
18
20 22
Dimension (mm)
990*1740*845 1340*1740*845
Fan quantity 1 1 1 1 1 2 2 2
Compressor quantity 1 1 1 1 1 2 2 2
PK 24 26 28 30 32
Dimension (mm)
1990*1740*845
Fan quantity 2 2 2 2 2
Compressor quantity 2 2 2 2 2

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner

Specificatie

Type Mini VRF Large VRF
Capaciteit PK 3HP-12HP 8HP-22HP
Voeding V/Ph/Hz 220-240V/1PH/50Hz
208-230V/1PH/60Hz
380-415V/3PH/50Hz & 60Hz
208-230V/3PH/60Hz
380-415V/3PH/50Hz & 60Hz
Cooling Capaciteit kW 8KW~33.5KW 25.2KW-61.5KW
kBtu/h 27.3-60kBtu/h 86-209.8kBtu/h
Power input kW 5.78-14.4kW 17-27.65kW
EER kW/kW 3.32-3.69 3.02-4.72
Verwarming Capaciteit kW 9KW-37.5KW 27.4KW-69KW
kBtu/h 92-191kBtu/h 27.4KW-69KW
Power input kW 5.41-14kW 15.8-26.08kW
COP kW/kW 3.56-4.27 4.11-5.5
Comperssors Type DC inverter
Fan motors Type DC inverter
Max.ESP Pa 85 85
Koelmiddel Type R410A
Aiflrow rate m³/h m³/h 3300-8000 15000-17000
dB(A) dB(A) 45-60 58-63
Ambient temp Cooling ºC -5-50ºC -5-55ºC
Verwarming ºC -20-30ºC -30-30ºC

Onze voordelen

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner
LONG PIPE & HEIGHT DIFFERENCE
1.The total pipe length: 1000 M.
2.The longest pipe length: 200 /240M.
3.Height deference:Outdoor unit.
Above<90M<90M.

4.Outdoor unit below<110M.
5.Height difference between indoor units: 30M.
6.Length from first indoor distributor to last indoor unit 90 M.
7.Communication wire length can be upto 1000m.

CONTROLLERS AND SOFTWARE

SIMPLIFY CENTRALIZED CONTROLLER

Easy to install.Controller connects to outdoor units only.
1 Controller can control max. 100 indoor units.
Operation mode restriction.
Error or protection code display
Can control single unit or all units together

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner

INDOOR UNITS QUANTITY
Max. 100 Indoor units can be connected in ONE system.

WIRELESS REMOTE CONTROLLERS
Indoor unit address inquiry.
Indoor unit address setting.
Temperature setting.
Operation mode setting.
Fan speed setting.
Timer function.

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner

SERVICE WINDOW ON FRONT COVER
Thanks to the service window, checking outdoor
unit’s status and setting is now easy, no need to
remove the front cover.

WIDE OUTDOOR OPERATION RANGE(380V)

Max.cooling operating temperature is up to 55°C.
Low ambient temperature of cooling mode can be downto-10ºC.

Hotel HVAC Solution R410A Vrv Vrf System Indoor Outdoor Units Manufacturer Commerial Central Air Conditioner