説明
Support a wide variety of system designs
Must PC1600 Charge Controllers truly represent innovation in Maximum Power Point Tracking (MPPT) technology, which enables them to increase the yield from a solar photovoltaic (PV) array as much as 30% over conventional designs. PC1600 Charge Controllers support a wide variety of system designs, battery chemistries, and integrate seamlessly in terms of system data management and programming.
PV system designers met the challenge of delivering both grid-tied savings during normal times and off-grid independence during emergencies with 1-phase arrays of Must IPV3000W/IPV5000W inverter/chargers powering your house. This system saved money on utility bills, supply essential power during emergencies (all with one versatile system).
特徴:
- LCD display , easy to operate on LCD screen
- Multi stage charging (3-stage charging , parallel charging and equalized charging function)
- BTS – Battery remote temperature sensor terminal
- Enable to charge Li-thium, Gel , lead-acid battery
- With RS485 & USB communication port
- Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit
SPECIFICATIONS:
MODEL | PC18-6015F | PC18-8015F | ||
Nominal Battery System Voltage | 12V/24V/48VDC (Auto detection); 36V(setting) | |||
CONTROLLER INPUT | ||||
Battery Voltage | 12V | 24V | 36V | 48V |
Maximum Solar Input Voltage | 100V | 145V | ||
PV Array MPPT Voltage Range | 15-95V | 30-130V | 45-130V | 60-130V |
Max PV Input Power(12V) | 938W | 1250W | ||
Max PV Input Power(24V) | 1875W | 2500W | ||
Max PV Input Power(36V) | 2813W | 3750W | ||
Max PV Input Power(48V) | 3750W | 5000W | ||
BATTERY | ||||
Charging Set points | Absorption Stage | Float Stage | ||
Flooded Battery | 14.2V/28.4V/42.6V/56.8V | 13.7V/27.4V/41.1V/54.8V | ||
AGM/Gel/LEAD battery (Default) | 14.4V/28.8V/43.2V/57.6V | 13.7V/27.4V/41.1V/54.8V | ||
Over-charging voltage | 15.5V/30.0V/45.0V/60.0V | |||
Over-charging comeback voltage | 14.5V/29.5V/44.5V/59.0V | |||
Battery defect voltage | 10.0V/17.0V/25.5V/34.0V | |||
Temperature Compensation coefficient | -5mv/°C /cell (25°C vef) | |||
PATTERY | ||||
Peak Conversion efficiency | 98% (MPPT Efficiency 99%) | |||
Max Charging Current | 60 amps continuous @ 40°C ambient | 80 amps continuous @ 40°C ambient | ||
GENERAL SPECIFICATION | ||||
Radiating mode | Fan cooling | |||
DISPLAY & PROTECTION | ||||
Protections | Solar high voltage disconnect; Solar high voltage reconnect; Battery high voltage disconnect; Battery high voltage reconnect; High temperature disconnect; High temperature reconnect. | |||
MECHANICAL SPECIFICATIONS | ||||
Mounting | Wall mount | |||
Machine Dimension(W*H* D) | 152*85*294mm (per pcs) | |||
G.W(Kg) | 3Kg/pcs | |||
Package Dimension(W*H* D) | 612*308.2*235.6mm (5pcs/Carton) | |||
Gross Weight(Kg) | 17.4Kg(per Carton) | 19Kg(per Carton) | ||
OTHER | ||||
Environmental Rating | Indoor | |||
Operation Temperature Range | -25~55°C | |||
Ambient humidity | 0~90% relative humidity(non-condensing) | |||
Altitude | ≤3000m | |||
Loading(20GP/40GP/40HQ) | 3000個 / 6000個 / 7200個 |