Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

Modello numero.
MD0630T41A

Personalizzato
Personalizzato

Nome del prodotto
6mA DC 30mA AC Residual Current Detector Sensor

Attuale
DC Current 2~15mA, AC Current 3~100mA

Installazione
Cable & Pin Type

3 Ways Output
DC Alarm, AC Alarm, AC/DC Alarm

Certificato
TUV-IEC, CE-EMC

Utilizzo
Leakage/Residual Current Protection

Voltaggio
12V

Theory
Current Sensor

Accuracy
DC 0.2mA, AC 0.3mA

Pacchetto di trasporto
Cartons

Specifica
TBA

Marchio
IVY

Origine
Zhejiang, Cina

Codice HS
8536411000

Capacità produttiva
5, 000, 000.00/ Anno

Descrizione

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

Voltaggio 12V±20%
Attuale DC current 2~15mA, AC current 3~100mA
Accuracy DC±0.2mA, AC±0.3mA @ 25ºC
3 Ways Produzione DC alarm, AC alarm, AC/DC alarm
Operation Temperature Range -25~+80ºC
Installazione Cable & Spillo Tipo
Plastica Casing SIP encapsulation

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor
Caution of Leakage Sensor:

MD0630T41A is a high sensititivity AC DC leakage current sensor for electric vehice charging station,
which can also be called residual current sensor, residual current monitor (RCM), residual current device
(RCD), differential current sensor, leakage detection sensor, fault current sensor etc.

To satisfy new standards including IEC 62955,IEC 62752, IEC 61851-1,and UL 2231-1 eccetera, the charging
of electric vehicles requires leakage current sensors to avoid hazardous situations in cases where the
vehicle battery(DC) is connected to the home power supply(AC).

Generally, AC DC Sensitive residual current sensors can be used where DC and AC circuits are directly
connected and therefore AC DC leakage currents occur. our MD series leakage sensor would be required
to guarantee safety in the event of DC fault current. Used in Mode 2 and Mode 3 EV Charging.

This residual current sensor will detect DC and AC leakage currents in 50Hz/60Hz AC installations according
to IEC62955. It’s intended for use in Electric Vehicle charging stations, complies with the DC protection requirements
of IEC62955.
It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE
if a fault occurs.