Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

Modello numero.
KMAT Series

Pacchetto di trasporto
Export Standard Packing

Specifica
CE, ISO9001, TÜV, GC certification

Marchio
DENAIR

Origine
Cina

Codice HS
8414809090

Capacità produttiva
4, 000 Sets/Month

Descrizione

Heat Pump Air to Water Converter with Europe Energy Labels

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

Project Unit R134a Units R22 Units
Environmental side Dry bulb temperature ºC -35-21ºC -35-21ºC
Use side Water outlet temperature ºC 35-70ºC 35-55ºC
Water flow m3/h Rated Flow±15% Rated Flow±15%
Allowable voltage range V Rated voltage±5% Rated voltage±5%
Three-phase voltage imbalance rate / ±2% ±2%
Allowable frequency range HZ Rated frequency±2% Rated frequency±2%
Note if water outlet temperature is higher than 70ºC

Modello KMAD-100 KMAT-150 KMAT-200 KMAT-240 KMAT-280 KMAT-330
The refrigerant R134a
Riscaldamento KW 100 150 200 240 280 330
Input power
(rated condition)
KW 38 55 70 85 100 113
power supply 3φ-380V-50HZ
protective device Reverse phase loss protection, protezione da sovracorrente,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit 1
Energy control (%) 0,50,75,100
Refrigerant charge (kg) 100 150 160 180 200 220
Finned heat exchanger Copper tube wearing hydrophilic corrugated aluminum sheet
Fan Form Axial Flow
Flow (m3/h) 60000 60000 90000 90000 120000 120000
Power (kw) 6 6 9 9 12 12
Water side maximum pressure MPa Form Shell and tube heat exchanger
Water side maximum pressure MPa 1
Import and export pipe diameter DN65 DN80 DN100 DN100 DN125 DN125
Hot water flow 17.2 25.8 34.4 41.3 49 56.8
Water pressure drop 38 42 45 48 52 55
Running noisedB(UN) 75 77 78 80 81 82
Unit length(mm) 3360 3360 5000 5000 6000 6000
Unit width(mm) 2260 2260 2230 2230 2230 2230
Unit height(mm) 2500 2500 2500 2500 2500 2500
Unit weight(kg) 4000 4300 6400 6700 8100 8500
Running weight(kg) 4500 4800 7000 7300 8700 9200
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3 / h * kW;
2, The ambient temperature range: -25 ° C ~ 21 °C; Tot water temperature range: 35°C ~ 70°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate;
4. KMAD-100 unit is a heating and cooling unit, GB/T 25127.1-2010 national standard nominal cooling capacity is
5. for the upcoming product model.

Modello KMAT-130A* KMAT-190A* KMAT-290A* KMAT-350A KMAT-350AV
The refrigerant R22
Riscaldamento KW 130 190 290 350 350
Input power
(rated condition)
KW 45 65 98 118 120
power supply 3φ-380V-50HZ
protective device Reverse phase loss protection, protezione da sovracorrente,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit 1
Energy control (%) 0,50,75,100
Refrigerant charge (kg) 160 180 200 220 220
Finned heat exchanger Copper tube wearing hydrophilic corrugated aluminum sheet
Fan Form Axial Flow
Flow (m3/h) 60000 90000 120000 120000 120000
Power (kw) 6 9 12 12 12
Water side maximum pressure MPa Form Shell and tube heat exchanger
Water side maximum pressure MPa 1
Import and export pipe diameter DN80 DN100 DN125 DN125 DN125
Hot water flow 22.4 32.7 49 60.2 60.2
Water pressure drop 45 48 52 55 55
Running noisedB(UN) 80 80 82 85 85
Unit length(mm) 3500 5000 6000 6000 6000
Unit width(mm) 2230 2230 2230 2230 2230
Unit height(mm) 2500 2500 2500 2500 2500
Unit weight(kg) 4500 6200 8000 8500 8500
Running weight(kg) 5000 6700 8700 9000 9000
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3/h*kW;
2. The ambient temperature range: -35°C ~21°C; Tot water temperature range: 35°C ~55°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate.
4. for the upcoming product model.

FAQ

Q1: Are you factory or trade company?
A1: We are factory.

Q2: What the exactly address of your factory?
A2: NO. 366, YangzhuangBang Street, Pingxing Rd., Xindai Town, Pinghu, Zhejiang Province, Cina

Q3: Warranty terms of your machine?
A3: Two years warranty for the machine and technical support according to your needs.

Q4: Will you provide some spare parts of the machines?
A4: sì, Ovviamente.

Q5: How long will you take to arrange production?
A5: 380V 50HZ we can delivery the goods within 10 giorni. Other electricity or other color we will delivery within 22 giorni

Q6: Can you accept OEM orders?
A6: sì, with professional design team, OEM orders are highly welcome.

DENAIR Factory
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

DENAIR Exhibition
Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

DENAIR Customer Case:

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels

DENAIR Packing & Spedizione

Air Source, Air to Water Converter Swimming Pool Heat Pump for House Floor Heating with Europe Energy Labels