R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

מספר דגם.
AWXX

מקור כוח
Electrical

Power Type
AC

מַצָב
חָדָשׁ

חומר קירור
R410A/R407c/R134A/R22

Heat Exchanger
Plate/Tube in Tube

Compressor Brand
Copeland/Panasonic/Daikin

Compressor Type
Scroll

Electric Parts
World Famous Brand

Refrigerant Valves
Emerson

Energy Recovery
Optional

Running Condition
T1 Condition or T3 High Ambient Temperature

Colour
White(Standard) or Others

Used for
Commercial Building or Industrial Factory

חבילת הובלה
Fumigation-Free Wood Packaging

סִימָן מִסחָרִי
AMRTA or OEM

מָקוֹר
חרסינה

קוד HS
8418612090

קיבולת ייצור
6000PCS/שנה

תיאור

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

Cooling Capacity 8 kW ~ 50 קילוואט

Our Products Range

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

מאפיינים

Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents

compressor
Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators

Axial fan
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, provided with a protective outlet grille

Evaporator
High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element (option) and differential pressure switch, factory insulated with flexible close cell material

Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins,100% fully quality tested; sub cooling circuit to prevent freezing at the base (optional); protected with metal grill

Desuperheater
High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material(optional)

Refrigerant circuit

Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, thermostatic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset . The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve

Water circuit

Built with air vent valve, water drain connection, and female-threaded hydraulic connectors

Water pump (8kW-30kW), differential pressure switch

Expansion tank (8kW-30kW)

Electric panel

Consists of:

Compressor contactor

Compressor protection breaker

Fan motor protection breaker

Control circuit protection breaker

Phase sequence relay (only for 3-phase)

Programmable microprocessor controller

Optional

Additional electric heater embedded in the coils for defrosting in low temperature ambient. It must be factory installed

Stainless steel covering

Remote condenser

Tube in tube heat exchanger

Water circuit electric heater

Technical Data

דֶגֶם יְחִידָה 20 25 30 35 40 50
Cooling *
Cooling capacity קילוואט 21.5 24.8 30 35.6 41 50.6
Cooling input (without water pump) קילוואט 8.2 9.03 9.39 13.2 15.02 18.8
EER / 2.62 2.75 3.19 2.7 2.73 2.69
הַסָקָה **
Heating capacity קילוואט 26.3 29 34 41.8 47.2 60
Heating input (without water pump) קילוואט 8.7 9.23 9.43 14.3 15.57 20.45
COP / 3.02 3.14 3.61 2.92 3.03 2.93
Hermetic compressor
סוּג /
Quantity/ circuit / 2/2 2/2 2/2 2/2 2/2 2/2
Evaporator
סוּג /
Water flow מ3/h 3.7 4.3 5.2 6.1 7.1 8.7
Water side pressure drop kPa 38 39 42 50 52 52
Water connection size מ"מ DN40 DN40 DN40 DN40 DN40 DN40
Circulating pump
Power input קילוואט 0.75 0.75 0.92 ——— ——— ———–
Axial fans
Quantity Nr. 1 1 1 2 2 2
Airflow מ3/h 9000 9000 12580 17000 17000 22000
Overal dimension
Length מ"מ 1600 1600 1600 2000 2000 2000
Width מ"מ 900 900 900 900 900 900
גוֹבַה מ"מ 1080 1080 1080 1080 1080 1080
Noise level *** dB(א) 66 66 68 70 70 70
Net weight ק"ג 270 290 310 360 380 465

* Ambient temperature 35ºC; user side water in/out 12/7ºC.
** Ambient temperature 7ºC; user side water in/out 40/45ºC.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in an ideal field (fan side).

Production Process

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

World Famous Spare Parts

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

Product Pictures
R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump
R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

Our Factory and Certificates

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

Some Simple Overseas Projects

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump

Contact Us

R32 DC Inverter Free Cooling Air Cooled Industrial Glycol Water Chiller/Industrial Air Conditioner Air Cooled Chiller & Heat Pump