Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

מספר דגם.
RDS2

Output type
Dual

נוכחי מדורג
250א

Frequency
50/60הרץ

Rated Voltage
AC150-265V

Color
White

חבילת הובלה
קופסא קרטון

מִפרָט
CCC, לִספִירַת הַנוֹצרִים

סִימָן מִסחָרִי
RADIN

מָקוֹר
Zhejiang, חרסינה

קוד HS
8536500000

קיבולת ייצור
10000PCS/חודש

תיאור

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.

(RDS2 Automatic Transfer Switch 100AMPS 4 Poles with Built-in controller)

RDS2 Series
PC class automatic transfer switch

Adopt two in one out design, easy to wiring;
With “0” position technology, can be forced to “0” position under emergency situation to match the fire-linkage requirement; Optional multifunction Intelligent controller with Programmable high/low voltage protection, high/low frequency protection, adjustable transfer delay time, adjustable center delay time, build-in engine exerciser, fault transfer to “0” function is optional; Separate LCD display is optional, with RS485 communication function
Optional functions: Center delay, fault to “0” position, engine exerciser etc.
Frame current: 100, 160, 250, 630, 1600א. 2000א, 3200א.

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

סוּג B type controller E type controller G type controller
Motor control voltage AC220V/50Hz
Aux. כּוֹחַ / DC 24V GA Type GB Type GC Type
1, DC 12V
2, DC 24V
Passive Output AC 220V
Voltage Measuring Range AC 40 to 300V
Power Loss less or equal 10W
Working Position (Normal power ON, Reserve power ON, OFF) Three working position שְׁלוֹשָׁה (I power ON, II power ON, I/II power OFF)
Operating Mode Auto, Manual Auto, Manual, Remote Auto, Manual
Display Mode LED Indicator LCD Display LED Indicator
Runing Status LED Indicators I/II POWER; I/II ON
Voltage Display לֹא כן לֹא
Transfer Mode Auto Transfer and Recovery Auto Transfer auto recovery / Auto transfer no recovery Auto Transfer and Recovery
Source Priority Default no source priority Settable I/II/No Priority Default no source priority
Under voltage transfer value NO +/- 20% Adjustable NO
Over voltage transfer value NO +/- 20% Adjustable NO
Transfer Delay Function NO 0~180s Adjustable NO
Recovery Delay Function NO 0~180s Adjustable NO
Phase missing detect Single phase (A Phase) Three phase (א,ב,C Phase) Single phase (A Phase)
Generator control כן (one set DC2A relay contact)
Fire-linkage control כן (passive contact input, with one set NO passive feedback signal)
RS485 function NO כן NO
Frequency Protection NO +/-20% adjust NO
Engine Exerciser NO כן NO
ATS Features Comparing, RDS2Outdated type ATS
RDS2 Outdated type ATS
Automatic Changeover Switch for Generator ATS Power (RDS2 Series) Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
Certificates לִספִירַת הַנוֹצרִים, RoHS /
Flame-retardant Cover כן לֹא
Working voltage (L-N) Wide(150VAC-300VAC) Ordinary
Controller Intelligent and settable Simple, fixed function
I Power LED Indicator כן לֹא
II Power LED Indicator כן לֹא
I Power ON LED Indicator כן לֹא
II Power ON LED Indicator כן לֹא
Over/Under Voltage Protection כן לֹא
Over/Under Frequency Protection כן לֹא
Transfer Time Delay Settable Fixed
Generator Start/Stop Time Delay Settable לֹא
Engine Exciser(weekly, monthly etc.) כן לֹא
Phase Immbalance Protection כן (custom made) לֹא
גוֹדֶל Compact Larger
Copper Bar 2 Input 1 Output 2 Input 2 Output(some)
Operation Handle Iron(solid) Plastic(crispy)
Fuse כן לֹא
Outlook Distinguished & Elegant Common
Motor Brand CNDF Wuxi, inferior quality
Before Factory Testing Auto Testing Line/Manual Manual check

Dlivery Terms
Sea Shipment & Express & Air express

אריזה
Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
( Product Packaging, Product: RDS2)

About the Company

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS Controller Operation Units

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS and Controller Operation Units

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
Products Test Equipment

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS Switch Test Line

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
(Our Test Lab)

RADIN parts are TUV, CB, לִספִירַת הַנוֹצרִים, CCC certified, and the factory is ISO9001:2015 qualified.

שאלות נפוצות:
1. What’s the warranty term?
24 Monthes.
2.How long does it take to deliver my goods?
בדרך כלל, samples can be delivered in 2 ימים. Customer designed sampleswill be delivered in 3-7 ימים.
3. Do you offer sample?
כן, we offer sample order for customer to test the goods.
4. What kinds of payment terms do you accept?
We offer kinds of payment ways foe customer to chose from. T/T,L/C,Aliexpress,Western union etc.
5. What if there’s quality peoblem?
We offer replacement for the goods as soon as there is a quality problem with the goods, and the fright is on our account to cut down the customer’s loss to the lowest.

We are sure any of your questions will get our prompt reply, just leave the message!