RJ45 1000Mbps single channel Outdoor Gigabit Power over Ethernet Surge protector
דֶגֶם: SNH-RJ45/POE-OD
APPLICATIONS: Designed for Ethernet device in the outside not to be spoiled by lightning over-voltage, induced over-voltage and static discharge. CAT6, CAT5e and CAT5 compatible 802.3af 10/100/1000 Base-T Gigabit Ethernet protection LAN, FDDI,CDDI, ATM,WLAN PDH, SDH, SPDH Industrial control POE IP cameras outdoor |
|
FEATURES: Multi. Protection circuits, Gas-Tube + TVS technology Dual protection in Common mode and differential mode TVS array technology, low capacitance Multi-Strike Capability |
|
TECHNICAL PARAMETER: |
|
דֶגֶם | SNH-RJ45/POE-OD |
Electrical Parameter(Network & כּוֹחַ) | |
Nominal operating voltage Un | 48V |
מקסימום. continuous operating voltage Uc | 60V |
Nominal discharge current(8/20µs)ב | 3kA |
מקסימום. discharge current (8/20µs)Imax | 5kA |
Limiting voltage Up | |
Line-line (@6kV, 10/700µs) | ≤150V |
Line-line (@3kA, 8/20µs) | ≤150V |
Adapt transmission rate | 1000Mbps |
Insertion loss | ≤0.5dB |
Protection line | 1-8 |
Response time | 1ns |
Load current | 250mA |
בַּקָשָׁה | Cat. 6 one channel |
Mechanical characteristics | |
מֵמַד | 28(H)×87(W)×100(ל)מ"מ |
Weight per unit | 350ז |
Protection grade | IP65 |
Working conditions | Temperature: -40 אֶל 85ºC, Relative humidity: ≤95% |
Standards compliance | לִספִירַת הַנוֹצרִים, FCC, RoHS, ISO9001 |
INSTALLATION AND MAINTENANCE
a) The SPD should be connected in series between the protected device and the signal/power transmission channel.
b) The input terminal (IN) of the SPD should connect to the signal/power transmission channel, and the output terminal (OUT) of the SPD should connect to the protected device.
c) Connect earthing wire of the SPD to earthing bus-bar of the lightning protection system of the room or building.
d)No special duty needs to be carried out for maintenance. When problem arises and the SPD is suspected, check the system with SPD taken out of circuit. Should system recover, the SPD shall be regarded as a damaged unit and must be replaced immediately.