Descripción del producto:
Split heat pump water heater adopts higher heating exchange elements to provide you the most energy saving solution for sanitary hot water supply.Also,it is more space saving,you can install the outdoor unit on the external walls or on the balcony.
Split heat pump water heater adopts higher heating exchange elements to provide you the most energy saving solution for sanitary hot water supply.Also,it is more space saving,you can install the outdoor unit on the external walls or on the balcony.
Enamel Water Tank Brings You Healthier Water Quality
High pressure and fatigue resistance which pass 280,000 times pulse test.
High corrosion resistance because enamel coating makes the welding line of steel plate seperate with water, so with long working life.
Our Porcelain enamel tanks approved by
ESTA,WATER MARK,ETL,WRAS,EN12977-3.
High pressure and fatigue resistance which pass 280,000 times pulse test.
High corrosion resistance because enamel coating makes the welding line of steel plate seperate with water, so with long working life.
Our Porcelain enamel tanks approved by
ESTA,WATER MARK,ETL,WRAS,EN12977-3.
High Efficient Compressor
Being internationally-renowned brand dedicated compressor for heat pump, it is more reliable in system matching and quieter in operation.
Intelligent Defrosting
With intelligent defrosting design, it can revolutionarily solve the bottlenecks of heat exchangers in cold winter such as frosting and slow heating, etc, allowing you to spend a more comfortable winter.
1:1 Gold Ratio
The unit and water tank are matched with a gold ratio to eliminate the phenomenon of disharmony, so that it is more energy-saving and professional.
Being internationally-renowned brand dedicated compressor for heat pump, it is more reliable in system matching and quieter in operation.
Intelligent Defrosting
With intelligent defrosting design, it can revolutionarily solve the bottlenecks of heat exchangers in cold winter such as frosting and slow heating, etc, allowing you to spend a more comfortable winter.
1:1 Gold Ratio
The unit and water tank are matched with a gold ratio to eliminate the phenomenon of disharmony, so that it is more energy-saving and professional.
EEV, precise flow control
Wide working temperature range, faster and more accurate refrigerant flow control than capillary and mechanical expansion valve. Best choice to achieve higher efficiency and energy-saving.
Wide working temperature range, faster and more accurate refrigerant flow control than capillary and mechanical expansion valve. Best choice to achieve higher efficiency and energy-saving.
Unique hyfrophilic fin coil heat exchanger, large amount for air inlet
Air exchangers (fin-coil)with hydrophilic coating are strongly anti-corrosive and perform at high efficiency.
Air exchangers (fin-coil)with hydrophilic coating are strongly anti-corrosive and perform at high efficiency.
Real Images and Details:
Technical Parameters:
Modelo | KWS-150V | KWS-200V | KWS-300V |
Tank Capacity | 150L | 200L | 300L |
Inner Tank Material | Enamelled Steel (Steel BTC340R, 2.5milímetro ) |
Enamelled Steel (Steel BTC340R, 2.5milímetro) |
Enamelled Steel (Steel BTC340R, 2.5milímetro) |
Outer casing | Painted galvanized steel | Painted galvanized steel | Painted galvanized steel |
Tank Rated Working Pressure | 0.8MPa | 0.8MPa | 0.8MPa |
Waterproof grade | IPX4 | IPX4 | IPX4 |
Electric Element Power | 2000W | 2000W | 2000W |
Heat Pump Thermal Capacity | 3700W | 3700W | 3700W |
Rated Input Power | 870W | 870W | 870W |
Rated Current | 4.0A | 4.0A | 4.0A |
Water Heating Capacity | 80L/H | 80L/H | 80L/H |
máx.. Water Temperature | 55ºC | 55ºC | 55ºC |
Voltaje | ~220-240V / 50Hz | ~220-240V / 50Hz | ~220-240V / 50Hz |
Refrigerant | R410a | R410a | R410a |
Cop | 4.25 | 4.25 | 4.25 |
Inlet / Outlet size | ¾” | ¾” | ¾” |
Control Method | Wire Controller | Wire Controller | Wire Controller |
Noise Level | 50dB(A) | 50dB(A) | 50dB(A) |
Heat Pump Dimension | 780x245x555mm | 780x245x555mm | 780x245x555mm |
How It Works:
- The fan inhales ambient air transferring its energy to the refrigerant agent in the evaporator thus changing from liquid to gas.
- The gas is further heated by compression.
- In the condenser the gas transfers its accumulated heat to the water tank. As it gets colder it transforms back to fluid. The pressure of the fluid is further reduced by the expansion valve.