N º de Modelo.
DA/EHF

Position of Pump Shaft
Horizontal Pump

Pump Casing Combined
Horizontal End Suction Pumps

Impeller
Closed

Uso
Pump, Pumps, Fire Fighting

Voltaje
220V/380V/400V/415V/440V

Frequency
50Hz/60Hz

Estándar
los, FM, Nfpa20, ESTA, YO ASI

Casing Material
Cast Iron/Ductile Iron/SS304/SS316

Seal
Packing Seal/Mechanical Seal

Impeller Material
Cast Iron/SS304/SS316/Bronze

Temperatura de trabajo
Normal

Garantía
12 Months for Pump, 3 Months for Spare Parts

Color
Red

Speed
1450rpm/1750rpm/2900rpm/3500rpm

El tiempo de entrega
40 Días

Solicitud
Building Fire Fighting, etc.

Marca
Sele Fire

Paquete de transporte
Export Wooden Case Package

Marca comercial
SELE FIRE

Origen
China

Código hs
8413709990

Capacidad de producción
1000 Sets Per Month

Descripción

1.Descripción del producto

DA series centrifugal pump is specialized in pumping water, liquid, chemical substances, etc.. The rotation speed is 1450rpm, 1750rpm, 2900rpm, 3500rpm for optional. This water pump can be widely used in water transfer system, farmland irrigation ,fire water supply, urban drainage, cooling water circulation for air conditioner, sewage treatment and other fields.

2.Pump Technical Parameters

1.Flow:0-1080m3/h;
2.Cabeza:0-150metro;
3.Fuerza:0.75-315kilovatios;
4.Rotary speed:1450rpm,1750rpm,2900rpm,3500rpm
5..Temperatura:-15-120ºC.

3.Partial Models Specifications for Clients Choosing(More Information Pls Feel Free To Contact Us)

Modelo Capacidad Cabeza Rotation
Speed
Frequency Fuerza Eficiencia Impeller
Dia.
Diámetro
Shaft Motor Inlet Outlet
m3/h L/s metro r/min hz kilovatios kilovatios % milímetro milímetro milímetro
DA40/13 8.7 2.42 6.4 1450 50 0.26 0.55 59 139 65 40
14.5 4.03 6.0 0.33 0.55 71
17.4 4.84 5.6 0.37 0.55 72
18.0 5.00 25.3 2900 50 2.03 2.2 61
30.0 8.33 23.5 2.63 3 73
36.0 10.00 21.8 2.91 4 73.5
8.7 2.92 9.3 1750 60 0.37 0.55 59
14.5 4.86 8.7 0.49 0.75 71
17.4 5.84 8.2 0.54 0.75 72
21.7 6.03 36.9 3500 60 3.57 5.5 61
36.2 10.05 34.2 4.62 7.5 73
43.4 12.06 31.8 5.11 7.5 73.5
DA40/13A 8.1 2.26 5.6 1450 50 0.21 0.55 58 130 65 40
13.6 3.77 5.2 0.27 0.55 71
16.3 4.52 4.8 0.30 0.55 71
16.8 4.67 22.0 2900 50 1.63 2.2 62
28.0 7.79 20.2 2.11 3 73.2
33.7 9.35 18.5 2.32 3 73.2
8.1 2.73 8.2 1750 60 0.31 0.55 58
13.6 4.55 7.6 0.40 0.55 71
16.3 5.46 7.0 0.44 0.75 71
20.3 5.64 32.0 3500 60 2.86 4 62
33.8 9.40 29.4 3.70 5.5 73.2
40.6 11.28 26.9 4.07 5.5 73.2
DA40/13B 7.5 2.09 4.8 1450 50 0.17 0.55 56 120 65 40
12.5 3.48 4.3 0.21 0.55 69
15.0 4.17 3.9 0.23 0.55 68.5
15.5 4.31 18.5 2900 50 1.28 1.5 61
25.9 7.19 17.0 1.64 2.2 73
31.1 8.63 15.3 1.77 2.2 73
7.5 2.52 6.9 1750 60 0.25 0.55 56
12.5 4.20 6.3 0.31 0.55 69
15.0 5.04 5.7 0.34 0.55 68.5
18.7 5.21 26.9 3500 60 2.25 4 61
31.2 8.68 24.8 2.89 4 73
37.5 10.42 22.3 3.12 4 73
DA40/13C 6.9 1.91 4.0 1450 50 0.15 0.55 51 110 65 40
11.5 3.19 3.6 0.18 0.55 64
13.8 3.83 3.3 0.19 0.55 63.5
14.2 3.96 15.5 2900 50 1.00 1.5 60
23.7 6.59 13.7 1.23 1.5 72
28.5 7.91 12.2 1.31 2.2 72
6.9 2.31 5.8 1750 60 0.21 0.55 51
11.5 3.85 5.3 0.26 0.55 64
13.8 4.62 4.8 0.28 0.55 63.5
17.2 4.77 22.6 3500 60 1.77 2.2 60
28.6 7.96 20.0 2.16 3 72
34.4 9.55 17.8 2.31 3 72
DA40/13D 6.3 1.74 3.3 1450 50 0.11 0.55 50.5 100 65 40
10.4 2.90 3.0 0.15 0.55 58
12.5 3.48 2.6 0.15 0.55 58
12.9 3.60 12.5 2900 50 0.76 1.1 58
21.6 5.99 11.0 0.92 1.5 70
25.9 7.19 9.5 0.97 1.5 69
6.3 2.10 4.8 1750 60 0.16 0.55 50.5
10.4 3.50 4.3 0.21 0.55 58
12.5 4.20 3.8 0.22 0.55 58
15.6 4.34 18.2 3500 60 1.34 2.2 58
26.0 7.23 16.0 1.62 2.2 70
31.2 8.68 13.8 1.71 2.2 69

4.Pump Features


5.Aplicaciones
UL/FM Approved Fire Fighting System Diesel Engine Driven Centrifugal End Suction Fire Pump, Nfpa Listed Fire Fighting Water Pump, Diesel Fire Pump UL/FM
6.Nuestros servicios

1. Entrega: Delivery time will be on time as the contract. Usually, our company need 35 working days for diesel engine pump, and for bare shaft pump, it takes 25 días laborables,

2. Garantía: 12 month for the pump body, 3 month for the main working parts.

3. Paquete: We use plywood case to pack our pump, which is durable for ocean transport.

4. On-sales Service: we will clear show you everything in fact when you place an order with us. We will
take photos or videos to show you our production situation, and report the production situation to you.

5. Calidad: we will test our pump before delivery, and we will follow up the pump working conditions per three months when the pump put into use. If you need spare parts, we can send to you in 1 o 2 semanas.

7.Our Factory
UL/FM Approved Fire Fighting System Diesel Engine Driven Centrifugal End Suction Fire Pump, Nfpa Listed Fire Fighting Water Pump, Diesel Fire Pump UL/FMUL/FM Approved Fire Fighting System Diesel Engine Driven Centrifugal End Suction Fire Pump, Nfpa Listed Fire Fighting Water Pump, Diesel Fire Pump UL/FM

Welcome to visit our factory!
All My Striving,For Your Satisfaction.
*********************************************************************************************
Company:Jiujiang SELE(DEFU) Fire Fighting Equipment Co.,Ltd

Head Office: Wenzhou DEFU Machinery Co.,Ltd
Fábrica:Shanghai Y&L Pump Co.,Ltd