Split Core Current Transformer with Ukca, los, ESTA

N º de Modelo.
SCT

Código hs
8504500000

Capacidad de producción
1000k

Descripción

Split core CT with UL2808,UL.CE,UKCA

SPLIT CORE CURRENT TRANSFORMERS

The SCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The SCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.

Características:
1:The structure of the self-locking, safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
4:Isolated plastic case recognized according to UL94-V0
5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs


Aplicaciones:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition equipment and automationcontrol system.
3:Current, power and energy monitoring device.

4:Relay protection device.

Technique Index:

Electrical Parameter Mechanical Parameter
Frequency 50-2KHz Case PA/UL94-V0
Rated Input 5A-200A Bobbin PBT
Rango de medición 10%In-120%In Core Silicon steel
Rated Output 0.333V(C.A.)or 0-500mA Internal structure Epoxy
Ratio ≤ ± 1.0% Construcción Tie
Phase angle ≤ ±60min Operation Temp -25oC~+75oC
Dielectric strangth 2.5KV/1mA/1min Operating Humidity ≤85%
Resistencia de aislamiento DC500V/100MΩ min Output Connection UL1015 20AWG Wire2.5m




Accuracy class characteristics:

Especificación:

PCT-T06

Split Core Current Transformer with Ukca, los, ESTA

MODELO PCT-6
Current Ratio 5A/2.5mA 10A/5mA 20A/10mA
Primary Current 5A 10A 20A
Max.Current 30A 30A 300A
Producción 2.5mamá 5mamá 10mamá
Load Resistance 200Oh 100Oh 50Oh
Class 0.5/1.0
Turns Ratio 2000:1 2000:1 2000:1
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installablmi
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T10

Split Core Current Transformer with Ukca, los, ESTA

MODELO PCT-10
Current Ratio 5A/2.5mA 20A/10mA 60A/20mA 75A/25mA 1~75A/0.333V
Primary Current 5A 20A 60A 75A 1~75A
Max.Current 60A 60A 750A 75A 1~75A
Producción 2.5mamá 10mamá 20mamá 25mamá 333mV
Load Resistance 400Oh 100Oh 50Oh 20Oh /
Class 0.5/1.0
Turns Ratio 2000:1 2000:1 3000:1 3000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installablmi
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T16

Split Core Current Transformer with Ukca, los, ESTA

MODELO PCT-16
Current Ratio 100A/33.3mA 100A/40mA 120A/40mA 200A/66.7mA 100~200A/0.333V
Primary Current 100A 100A 120A 200A 100~200A
Max.Current 120A 120A 120A 240A 240A
Producción 33.3mamá 40mamá 40mamá 66.7mamá 333mV
Load Resistance 50Oh /
Class 0.5/1.0
Turns Ratio 3000:1 2500:1 3000:1 3000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installablmi
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T24

Split Core Current Transformer with Ukca, los, ESTA

MODELO PCT-24
Current Ratio 100A/40mA 200A/40mA 200A/66.7mA 400A/80mA 100~400A/0.333V
Primary Current 100A 200A 200A 400A 100~400A
Max.Current 150A 240A 240A 480A 4800A
Producción 40mamá 40mamá 66.7mamá 80mamá 333mV
Load Resistance 50Oh /
Class 0.5/1.0
Turns Ratio 2500:1 5000:1 3000:1 5000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installablmi
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T36

Split Core Current Transformer with Ukca, los, ESTA

MODELO PCT-36
Current Ratio 300A/100mA-5a
Primary Current 300A
Max.Current 360A
Producción 100mA-5a
Load Resistance 50Oh
Class 0.5/1.0
Turns Ratio 3000:1
Protection Level 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installablmi
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation