IGBT Battery Charger and Discharger Charging Machine Production Line for Battery

Control Method
IGBT Rectification

Paquete de transporte
Export Standard

Especificación
1200*800*2200 (milímetro)

Marca comercial
Better

Origen
China

Código hs
8504401990

Capacidad de producción
50000PCS/ Year

Descripción

Battery Charger & Discharger

1. Main Technical Parameters

Maximum output voltage: 360V, 320V, 350V
Maximum charge current: 10A, 20A, or as per the user’s requirement
Maximum discharge current: 10A, 20A, or as per the user’s requirement
Control Method: IGBT rectification
Circuit Quantity of Each Machine: 24 circuits, or as per the user’s requirement
Input Current: 3Φ380V AC (-5%; +10%) 50HZ

2. Technical Index:
* Voltage control accuracy: ≤±0.5%F.S (F.S=360V)
* Current control accuracy: ≤±0.3%F.S (F.S=10A)
* Time control accuracy: ≤±10S/24H
* Voltage control range: 10%~100%F.S (F.S=360V)
* Current control range: 1%~100% F.S (F.S=10A)
* Charge current: 0~10A, or as per the user’s requirement
* Discharge current: 0~10A, or as per the user’s requirement
* Discharge capacity recovery efficiency: ≥95%
* Equipment charge efficiency: ≥95%
* Direct current output ripple: ≤5% DC (battery loaded 100% current)
* Power factor: ≥95% (más que 50% load)
* Output harmonic content: <5%
* Power factor compensation: built-in, without reactive power compensation
* Harmonic treatment: built-in, without any treatment
* Electricity supply transformer utilization: ≥90%
* Electricity saving benefit: 5%~8% (compared with silicon controlled)
* Equipment dimension: 1200*800*2200 (milímetro)

3. Función:
* Set up formation process program and parameter for all kinds of batteries; The program process can be set with 30 steps. The preset processes can be stored in the computer, and can be recalled to any designated charger and discharger. The processes can be uploaded to the computer via the monitor software.
* With the working mode of constant current charge, constant voltage charge, constant voltage current-limiting charge, constant current voltage-limiting discharge, circulation and standby;
* With the function of stage switch mode for fixed time, fixed voltage, fixed current; and function of recording running data at a fixed time;
* With the function of data storage during over-current.