Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA

Αριθμός Μοντέλου.
QA105

Voltage
AC 220V

Element Number
Push-Pull Amplifier

Conductive Mode
ρε

Theory
Resistance Sensor

Aplication
Load Cell

Linearity
0.02%Fs

Input Signal
0~2mv/V

Πακέτο μεταφοράς
Inner Side Plastic Bags, Outside Carton Box

Προσδιορισμός
C2

Εμπορικό σήμα
QYE

Προέλευση
Ce

Κωδικός HS
8423900000

Παραγωγική ικανότητα
10000pieces/Month

Περιγραφή

Load Cell Sensor Amplifier Transmitter strain gauge transducer 0-5V 0-10V 4-20MA

Feature

1. Using full-blown lines and reliable device for amplifying and transmitting of the resistance strain
type weighing transducer,
outputting the signal: 0~10V ,(0~5V) or 4~20mA, connecting with PC or PLC to consist measuring control system;
2. Input signal: 0~2mv/v;
3. Output signal: 105 outputting 0~10V (0~5V), 106 outputting 4~20mA;
4.Supply power: DC24V(min18v,max36v);
5.Dimensions(mm):100×68×55;
6. Linearity: 0.02%FS.
Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA
Technique Datas:

Linearity

0.02%FS

input signal range

6~30mA

Zero range

0~60%

Adjustable full-scale range

6~30mV

Sensor excitation power

9 ~ 12V adjustable output voltage, current limiting with short circuit protection ≤200mA

Zero hysteresis range

Voltage signal: 0 ~ 5V

Current signal: 0 ~ 20mA (load resistance ≤500Ω)

Excitation power supply

temperature stability

25ppm/ºC

Sensor excitation power

9 ~ 12V adjustable output voltage, current ≤200mA, with short circuit current limit protection

Power supply

AC220±22V,50HZA or DC24±1V or DC12±1V

Power consumption About

5VA

Working temperature

-10~50ºC

temperature

≤80%RH

Wiring Box

160 × 152 × 67mm (height × width × thickness)

(Not including connectors)

92(μεγάλο)×63(W)×32(H)mm,48(μεγάλο)×33(W)×17(H)mm

Electrical connection

1. QA-105/106 are all using inputting/outputting joints, connecting separately the input signal of transducer and the output signal of module.

2. The request for signal cable: transmitter use plastic waterproof joint,;

The request for Cable diameter:6±0.3(mm).
3. The connection type of the transducer signal inputting terminals corresponding to connecting line terminals:
V+: Excitation +;
GND: Excitation -;
IN+: output signal +;
IN-: output signal -.
4. The connection type of the module signal inputting terminals
corresponding to connecting line terminals:
OUT: the terminal of transmitter signal outputting;
DC: 24V amplifying/Excitation+;
GND: amplifying / Excitation-ground.

Load Cell Sensor Amplifier Transmitter Strain Gauge Transducer 0-5V 0-10V 4-20mA

The adjusting and the ordering instrument of the product:

1.The correct connecting the transducer with the supply power, after 10 minutes powering on, when the transducer is out off load ,to adjust the potentiometer which showsZmaking the outputting for 0Vor 4mA; Adding to the standard load, adjusting the potentiometer which showsSmaking the outputting for 10V(5V) or 20mA.
2. The transducer power supply of 105 και 106 amplification transmitter:
Πρότυπο: 15V, Delicate: 10V.
3. Please explain the sensitivity and the output resistance of the
transducer, when ordering.