Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

Αριθμός Μοντέλου.
MD0630T41A

Προσαρμοσμένο
Προσαρμοσμένο

Product Name
6mA DC 30mA AC Residual Current Detector Sensor

Current
DC Current 2~15mA, AC Current 3~100mA

Εγκατάσταση
Cable & Pin Type

3 Ways Output
DC Alarm, AC Alarm, AC/DC Alarm

Πιστοποιητικό
TUV-IEC, CE-EMC

Χρήση
Leakage/Residual Current Protection

Voltage
12V

Theory
Current Sensor

Accuracy
DC 0.2mA, AC 0.3mA

Πακέτο μεταφοράς
Cartons

Προσδιορισμός
TBA

Εμπορικό σήμα
IVY

Προέλευση
Zhejiang, Κίνα

Κωδικός HS
8536411000

Παραγωγική ικανότητα
5, 000, 000.00/ Year

Περιγραφή

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

Voltage 12V±20%
Current DC current 2~15mA, AC current 3~100mA
Accuracy DC±0.2mA, AC±0.3mA @ 25ºC
3 Ways Output DC alarm, AC alarm, AC/DC alarm
Operation Temperature Range -25~+80ºC
Εγκατάσταση Cable & Pin Type
Plastic Casing SIP encapsulation

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor
Caution of Leakage Sensor:

MD0630T41A is a high sensititivity AC DC leakage current sensor for electric vehice charging station,
which can also be called residual current sensor, residual current monitor (RCM), residual current device
(RCD), differential current sensor, leakage detection sensor, fault current sensor etc.

To satisfy new standards including IEC 62955,IEC 62752, IEC 61851-1,and UL 2231-1 και τα λοιπά, the charging
of electric vehicles requires leakage current sensors to avoid hazardous situations in cases where the
vehicle battery(DC) is connected to the home power supply(AC).

Generally, AC DC Sensitive residual current sensors can be used where DC and AC circuits are directly
connected and therefore AC DC leakage currents occur. our MD series leakage sensor would be required
to guarantee safety in the event of DC fault current. Used in Mode 2 and Mode 3 EV Charging.

This residual current sensor will detect DC and AC leakage currents in 50Hz/60Hz AC installations according
to IEC62955. It’s intended for use in Electric Vehicle charging stations, complies with the DC protection requirements
of IEC62955.
It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE
if a fault occurs.