Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

Αριθμός Μοντέλου.
RDS2

Output type
Dual

Rated Current
250ΕΝΑ

Συχνότητα
50/60Hz

Rated Voltage
AC150-265V

Χρώμα
Λευκό

Πακέτο μεταφοράς
Carton Box

Προσδιορισμός
CCC, CE

Εμπορικό σήμα
RADIN

Προέλευση
Zhejiang, Κίνα

Κωδικός HS
8536500000

Παραγωγική ικανότητα
10000ΤΕΜ/Μήνας

Περιγραφή

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.

(RDS2 Automatic Transfer Switch 100AMPS 4 Poles with Built-in controller)

RDS2 Series
PC class automatic transfer switch

Adopt two in one out design, easy to wiring;
With “0” position technology, can be forced to “0” position under emergency situation to match the fire-linkage requirement; Optional multifunction Intelligent controller with Programmable high/low voltage protection, high/low frequency protection, adjustable transfer delay time, adjustable center delay time, build-in engine exerciser, fault transfer to “0” function is optional; Separate LCD display is optional, with RS485 communication function
Optional functions: Center delay, fault to “0” position, engine exerciser etc.
Frame current: 100, 160, 250, 630, 1600ΕΝΑ. 2000ΕΝΑ, 3200ΕΝΑ.

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)

Type B type controller E type controller G type controller
Motor control voltage AC220V/50Hz
Προς την. Power / DC 24V GA Type GB Type GC Type
1, DC 12V
2, DC 24V
Passive Output AC 220V
Voltage Measuring Range AC 40 to 300V
Power Loss less or equal 10W
Working Position (Normal power ON, Reserve power ON, OFF) Three working position Three (I power ON, II power ON, I/II power OFF)
Operating Mode Auto, Manual Auto, Manual, Remote Auto, Manual
Display Mode LED Indicator LCD Display LED Indicator
Runing Status LED Indicators I/II POWER; I/II ON
Voltage Display Οχι Ναί Οχι
Transfer Mode Auto Transfer and Recovery Auto Transfer auto recovery / Auto transfer no recovery Auto Transfer and Recovery
Source Priority Default no source priority Settable I/II/No Priority Default no source priority
Under voltage transfer value ΟΧΙ +/- 20% Adjustable ΟΧΙ
Over voltage transfer value ΟΧΙ +/- 20% Adjustable ΟΧΙ
Transfer Delay Function ΟΧΙ 0~180s Adjustable ΟΧΙ
Recovery Delay Function ΟΧΙ 0~180s Adjustable ΟΧΙ
Phase missing detect Single phase (A Phase) Three phase (ΕΝΑ,B,C Phase) Single phase (A Phase)
Generator control Ναί (one set DC2A relay contact)
Fire-linkage control Ναί (passive contact input, with one set NO passive feedback signal)
RS485 function ΟΧΙ Ναί ΟΧΙ
Frequency Protection ΟΧΙ +/-20% adjust ΟΧΙ
Engine Exerciser ΟΧΙ Ναί ΟΧΙ
ATS Features Comparing, RDS2Outdated type ATS
RDS2 Outdated type ATS
Automatic Changeover Switch for Generator ATS Power (RDS2 Series) Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
Πιστοποιητικά CE, RoHS /
Flame-retardant Cover Ναί Οχι
Working voltage (L-N) Wide(150VAC-300VAC) Ordinary
Controller Intelligent and settable Simple, fixed function
I Power LED Indicator Ναί Οχι
II Power LED Indicator Ναί Οχι
I Power ON LED Indicator Ναί Οχι
II Power ON LED Indicator Ναί Οχι
Over/Under Voltage Protection Ναί Οχι
Over/Under Frequency Protection Ναί Οχι
Transfer Time Delay Settable Fixed
Generator Start/Stop Time Delay Settable Οχι
Engine Exciser(weekly, monthly etc.) Ναί Οχι
Phase Immbalance Protection Ναί (custom made) Οχι
Μέγεθος Compact Larger
Copper Bar 2 Input 1 Output 2 Input 2 Output(some)
Operation Handle Iron(solid) Plastic(crispy)
Fuse Ναί Οχι
Outlook Distinguished & Elegant Common
Motor Brand CNDF Wuxi, inferior quality
Before Factory Testing Auto Testing Line/Manual Manual check

Dlivery Terms
Sea Shipment & Express & Air express

Συσκευασία
Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
( Product Packaging, Προϊόν: RDS2)

About the Company

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS Controller Operation Units

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS and Controller Operation Units

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
Products Test Equipment

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
ATS Switch Test Line

Automatic Changeover Switch for Generator ATS Power (RDS2 Series)
(Our Test Lab)

RADIN parts are TUV, CB, CE, CCC certified, and the factory is ISO9001:2015 qualified.

FAQ:
1. What’s the warranty term?
24 Monthes.
2.How long does it take to deliver my goods?
Normally, samples can be delivered in 2 ημέρες. Customer designed sampleswill be delivered in 3-7 ημέρες.
3. Do you offer sample?
Ναί, we offer sample order for customer to test the goods.
4. What kinds of payment terms do you accept?
We offer kinds of payment ways foe customer to chose from. T/T,L/C,Aliexpress,Western union etc.
5. What if there’s quality peoblem?
We offer replacement for the goods as soon as there is a quality problem with the goods, and the fright is on our account to cut down the customer’s loss to the lowest.

We are sure any of your questions will get our prompt reply, just leave the message!