15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation

Αριθμός Μοντέλου.
CHZ4

Εμπορικό σήμα
HEMG

Προέλευση
Κίνα

Παραγωγική ικανότητα
5000ΤΕΜ/Έτος

Περιγραφή

1&περίοδος;0 Instruction
The CHZ4(T)-12(15/27/38) KV/630A-1250A Providing the features of a traditional re-closer&κόμμα; plus the bene of up to date design optimized for automation&κόμμα; remote control and monitoring&κόμμα; now or in the future&περίοδος;by customer demand for improved return on capital investment in the distribution network to achieve optimum performance and reliability&κόμμα; making use of the latest available technology in insulation&κόμμα; vacuum interruption and microelectronics&περίοδος;
Three phase pole-top automatic circuit re-closer are designed and produced by the three kind of international advanced technology&κόμμα; as epoxy solid encapsulated technology&κόμμα; permanent magnetic actuating device&κόμμα; and intelligence control technology and so on&περίοδος;
The product is composite with solid dielectric insulted pole&κόμμα; permanent magnetic actuating device or motor actuating device&κόμμα; control unit&κόμμα; current transformer and vacuum interrupter and voltage sensor&περίοδος; Except the control unit is a single device&κόμμα; the others are combined together&κόμμα; compact frame&κόμμα; flexible design&κόμμα; εύκολο στη λειτουργία&περίοδος;
The CHZ4(T)-12(15/27/38) KV/630A-1250A three phase pole-top automatic circuit re-closer is for 12kV(15KV/27KV/38KV)&κόμμα;50/60Hz distribution system&κόμμα; has not only circuit breaker control and protection features&κόμμα; but also can automatically detect the lines running statement&περίοδος;
Once the load side line or equipment occur a fault&κόμμα; meet or exceed current setting the minimum starting current&κόμμα; it will be good at a per-determined action sequence&κόμμα; to identify the fault is transient or permanent&κόμμα; and auto-complete one to three re-closing&περίοδος;
2&περίοδος;0 Designing Standard
2&περίοδος;0&περίοδος;1 ANSI-IEEE-Std-C37&περίοδος;60-2003&κόμμα;
2&περίοδος;0&περίοδος;2 BS EN 60529-1992+Α2&άνω κάτω τελεία;2013
2&περίοδος;0&περίοδος;3 IEEE Std&περίοδος;C37&περίοδος;60-2013&κόμμα; IEEE Std C57&περίοδος;12&περίοδος;29-2014
2&περίοδος;0&περίοδος;4 JB7570-1994&κόμμα; and DL/T813-2002
2&περίοδος;0&περίοδος;5 IEC56&κόμμα; IEC694&κόμμα; IEC62271-111

3&περίοδος;Specification for Vacuum Circuit Breaker
3&περίοδος;1 Ratings for ZW32-12(15) KV Vacuum Circuit Breaker

Οχι&περίοδος; Είδος Unit Data for ZW32-12KV Data for ZW32-15KV
1 Rated Voltage KV 12 15
2 Rated insulation level
(phase to ground&κόμμα; phase to phase)
1 min Frequency withstand voltage Dry KV 42 50
Wet 34 45
Lighting Impulse Withstand Voltage(Peak) KV 75 110
3 Medium Interruption&άνω κάτω τελεία; Vacuum
4 Medium isolation&άνω κάτω τελεία; Solid polymer
5 Mechanism of operation (closing and shot)&άνω κάτω τελεία; Magnetic
6 Assembly&άνω κάτω τελεία; Suitable weather for substation
7 Environmental operating temperature&άνω κάτω τελεία; FROM -40ºC-+50ºC
8 Position indicator&άνω κάτω τελεία; Green-closed; Open-red
9 Minimum distance of contouring of the insulation MM 400 600
10 Rated Frequency Hz 50/60
11 Rated Current ΕΝΑ 630/800/1250
12 Rated Min Start-up Current Numerical ΕΝΑ ευκανόνιστος
Permissible deviation % ±10
13 Rated Fault Interrupter Capacity KA/3s 12&περίοδος;5/20
14 Rated Fault Symmetrical Making Current KA 12&περίοδος;5/20
15 Rated Short-Time Withstand Current KA 12&περίοδος;5/20
16 Rated Peak Withstand Current KA 12&περίοδος;5/20
17 Interrupting Time(Μέγ) (Cycle) s No more than 4
18 The conditions of different phase earthed fault short-circuit breaking current KA 17&περίοδος;3
19 Rated Cable Charging Breaking current ΕΝΑ 25
20 Rated Operating Sequence O-0&περίοδος;1s-CO-2s-CO-2s-CO-C
21 Rated Operation Voltage V AC/DC110/125/220/240
22 Rated Short-Circuit Current Breaking Times Time
90%~ 100% Rated Short-Circuit Current volume 16
45%~ 55% Rated Short-Circuit Current volume 44
15%~20% Rated Short-Circuit Current volume 56
23 Mechanical Life (Mechanical stability) Time/Unit Operation 15000
24 Current Transformer Primary Rated Current ΕΝΑ 600/1000
Secondary Rated Current 1 or 5
Accuracy Grade CL 0&περίοδος;2/5P20
Capability VA 15
25 Special Manual Closing Mechanism
optional
26 Earthing Solidly Earthed


3&περίοδος;2 Ratings for ZW32-27(38) KV Vacuum Circuit Breaker


Οχι&περίοδος;
Είδος Unit Data for ZW32-27KV Data for ZW32-38KV
1 Rated Voltage KV 27 38
2 Rated insulation level (phase to ground&κόμμα; phase to phase) 1 min Frequency withstand voltage Dry KV 65 95
Wet 50 80
Lighting Impulse Withstand Voltage(Peak) KV 145/150 185
3 Medium Interruption&άνω κάτω τελεία; Vacuum
4 Medium isolation&άνω κάτω τελεία; Solid polymer
5 Mechanism of operation (closing and shot)&άνω κάτω τελεία; Magnetic
6 Assembly&άνω κάτω τελεία; Suitable outdoor for substation or pole mounted
7 Environmental operating temperature&άνω κάτω τελεία; FROM -40ºC-+50ºC
8 Position indicator&άνω κάτω τελεία; Green-closed; Open-red
9 Minimum distance of contouring of the insulation MM 680 900
10 Rated Frequency Hz 50/60
11 Rated Current ΕΝΑ 200ΕΝΑ/400ΕΝΑ/630ΕΝΑ/1250ΕΝΑ
12 Rated Min Start-up Current Numerical ΕΝΑ Adjustable
Permissible deviation % ±10
13 Rated Fault Interrupting Capacity KA/3S 12&περίοδος;5/20
14 Rated Symmetrical Making Current KA 12&περίοδος;5/20
15 Rated Short-Time Withstand Current KA 12&περίοδος;5/20
16 Rated Peak Withstand Current KA 12&περίοδος;5/20
17 Interrupting time(Μέγ)(Cycle) S Not more than 4
18 The conditions of different phase earthed fault short-circuit breaking current KA 12&περίοδος;5 20
19 Rated Cable Charging Breaking current ΕΝΑ 25
20 Rated Operating Sequence O-0&περίοδος;1s-CO-2s-CO-5s-CO-C
21 Rated Operation Voltage V AC/DC110/125/220/240
22 Rated Short-Circuit Current Breaking Times Time
90%~ 100% Rated Short-Circuit Current volume 16
45%~ 55% Rated Short-Circuit Current volume 44
15%~20% Rated Short-Circuit Current volume 56
23 Mechanical Life (Mechanical stability) Time/unit Operation 10000
24 Current Transformer Primary Rated Current ΕΝΑ 600/1000
Secondary Rated Current 1 or 5
Accuracy Grade CL 0&περίοδος;25/5P20
Capability VA 15
25 Special Manual Closing Mechanism Option
26 Farthing Solidly Earthed


4&περίοδος;Intelligent Controller Communications Cubicle
The product is supplied complete with an CHK4(T/S) series controller to achieve the various functions Including of measurement&κόμμα; protection&κόμμα; control and communication requirements&περίοδος; The controller can achieve the functions are as follows&άνω κάτω τελεία;

CHK4 CONTROLS FUNCTIONS AND CHARACTERISTICS
1&περίοδος; Control panel is operated by manual or PC
2&περίοδος; Remote control is by through SCADA
3&περίοδος; Total time maximum opening 3 cycles/50ms for 60hz
4&περίοδος; Re-close time and programming step Programmable
5&περίοδος; Independent calibration groups&κόμμα; minimum
Automatic Protection Group Selection is used to change the protection&κόμμα; group depending on the direction of power flow&περίοδος; This allows the re-closer to be correctly graded with devices downstream regardless of the power flow direction&περίοδος;
3/4
each of which can be configured
with completely separate protection characteristics with different inverse time curves and setting currents&περίοδος; The number of protection groups available to the operator can be configured&κόμμα; thereby restricting or enabling access to protection settings as required
6 Operation with dead line With battery bank if AC power is lost 1&περίοδος;Back up battery bank power for 48hours without charging
2&περίοδος;100times operation within 48hours
3&περίοδος;Battery bank is charged by intelligent charger in controller cabinet from outside PT
7&περίοδος; It is with Control and microprocessor protection
8&περίοδος; Selection of number of operations fast 0-4 from IEC curve
9&περίοδος; Selection of number of slow operations 0-4 from IEC curve
10&περίοδος; Selection of number of lock operations 1-4 IEC curve
11&περίοδος; Buttons with indicators (LED’s)&περίοδος; Applicable control with microprocessor relay
12&περίοδος; Modification of curves by time (dial) tap in current and adding time-definite FOR IEC 5 Curve and IEEE 3 curve
13&περίοδος; Minimum programmable LED’s&περίοδος; It applies to control with microprocessor relay&περίοδος; 4 (u)
14&περίοδος; Automatic Re-closer locking
15&περίοδος; Remote operation lock
16&περίοδος; Levels of access codes to configuration
17&περίοδος; Fault recorder
18&περίοδος; FOR PROTECTION CURRENT TRANSFORMERS&άνω κάτω τελεία;
18&περίοδος;1 Relation For Phases 1000/600/400/200/100&άνω κάτω τελεία;1/5
18&περίοδος;1&περίοδος;1 Precision for protection&άνω κάτω τελεία; +/- 5%
18&περίοδος;1&περίοδος;2 Material of the bushings Polymer
18&περίοδος;2 Relation for Ground 200/100/50&άνω κάτω τελεία;1/5(POTION)
18&περίοδος;2&περίοδος;1 Precision for protection 5P
18&περίοδος;2&περίοδος;2 Material of the bushing Polymer
19&περίοδος; FEATURES OF THE ELECTRONIC CONTROL
19&περίοδος;1 Type of installation&άνω κάτω τελεία; Outdoor for mounting substation or pole
19&περίοδος;2 Degree of protection&άνω κάτω τελεία; IP65/IP54
19&περίοδος;3 Access Front
19&περίοδος;4 Memory type&άνω κάτω τελεία; Non-volatile
20&περίοδος; THE CONTROL UNIT SHOULD INCLUDE&άνω κάτω τελεία;
20&περίοδος;1 Liquid crystal display LCD(3″x1″/77mmx27mm)
20&περίοδος;2 Membrane keyboard
20&περίοδος;3 LED’s for indication of the State of the control&κόμμα; Re-closer (open/close) and the shooting conditions
21&περίοδος; OPERATION BUTTONS TO ENABLE / DISABLE THE FOLLOWING FUNCTIONS&άνω κάτω τελεία;
21&περίοδος;1 Ground-fault trip
21&περίοδος;2 Automatic Re-closer
21&περίοδος;3 Remote control
21&περίοδος;4 Buttons for closure and manual (local) tripping of the unit
21&περίοδος;5 Function of hot line tag to configurable buttons for change of setting and activation of control logic or blocking local group&περίοδος;
22 PROTECTION FUNCTIONS
22&περίοδος;1 Instantaneous over current for phase&κόμμα; neutral and negative sequence 50 relays PGQ/50N
22&περίοδος;2 Timed over current for phase&κόμμα; neutral and negative sequence 51 relays PGQ/51N
22&περίοδος;3 Sequence Components
Negative&κόμμα; positive and zero phase sequence currents and voltages can be
monitored and logged&περίοδος;
In addition&κόμμα; the negative phase sequence current protection can be used for
detection of low-level phase-to-phase faults in the presence of high level three phase
loads&περίοδος; Inverse Time&κόμμα; Definite Time and Instantaneous operation is available&περίοδος;
Setting current range&άνω κάτω τελεία; 10 – 1260 ΕΝΑ
22&περίοδος;4 Sequence Coordination Sequence Coordination allows a recloser to coordinate it’s trip sequence with
another recloser downstream
22&περίοδος;5 Auto-re-closer Relay 79 (sequence 1&κόμμα;2&κόμμα;3&κόμμα;4)
Operating Sequence
Reclose times are individually selectable&περίοδος; The operating sequence is defined by&άνω κάτω τελεία;
O – 1st rtCO – 2nd rtCO – 3rd rtCO
where rt = reclose time&περίοδος;
where O = open&περίοδος;
where C = close&περίοδος;
1st Reclose Time range&άνω κάτω τελεία; 0&περίοδος;2 – 180 sec
2nd Reclose Time range&άνω κάτω τελεία; 2&περίοδος;0 – 180 sec
3rd Reclose Time range&άνω κάτω τελεία; 2&περίοδος;0 – 180 sec
Timing resolution&άνω κάτω τελεία; 0&περίοδος;1 sec
Recovery/ Reset Time&άνω κάτω τελεία; 0&περίοδος;1 – 180 sec
Sequence Reset Timing resolution&άνω κάτω τελεία; 1 sec
22&περίοδος;6 Trips to Lockout Overcurrent and fault trips to lockout are selectable between 1 and 4&περίοδος; A separate
setting is available for Sensitive Earth Fault and Negative Phase Sequence&περίοδος;
22&περίοδος;7 Loss of phase
Loss of phase protection trips the re-closer if phase-earth voltage on one or two&κόμμα; phases falls below a set voltage threshold for a set length of time&περίοδος;
Threshold voltage range&άνω κάτω τελεία; 2 – 15kV
Voltage resolution&άνω κάτω τελεία; 1V
Time range&άνω κάτω τελεία; 0&περίοδος;1 – 100 sec
Time resolution&άνω κάτω τελεία; 0&περίοδος;1 sec
22&περίοδος;8 Live load blocking
Live load blocking prevents a re-closer from closing if any of the load side terminals
are live&περίοδος;
Live Load Threshold Voltage range&άνω κάτω τελεία; 2 – 15kV
22&περίοδος;9 Dead lockout
Dead lockout prevents a reclose unless one or more of the source side or load side
terminals are live&περίοδος; If all terminals are dead&κόμμα; then the controller goes to lockout
22&περίοδος;10 Envelope and low frequency
This feature trips the re-closer when the system frequency exceeds the under and
over frequency trip threshold values&περίοδος; Frequency tripping range&άνω κάτω τελεία; 45 – 65 Hz
Relay 81
Frequency calculation&άνω κάτω τελεία; Once per cycle over a two-cycle period
Number of under/over frequency cycles before tripping&άνω κάτω τελεία; 2 – 1000
Accuracy&άνω κάτω τελεία; ±0&περίοδος;05Hz
22&περίοδος;11 Over voltage Relay 59
22&περίοδος;12 Low voltage Relay 27
22&περίοδος;13 Distance Relay 21
22&περίοδος;14 Directional blocking
Directional protection
67 relay PGQ/67N
a protection feature that restricts tripping on faults to a
designated side of the re-closer&περίοδος; It prevents nuisance tripping if network
conditions are causingfalseearth faults&περίοδος; In radial systems&κόμμα; Directional Blocking
prevents nuisance tripping by blocking faults in the source direction and only responding to faults in the load direction&περίοδος;
Distinct protection for faults in the forward and reverse direction&περίοδος; A forward fault may
use a different time-current curve and settings to a reverse fault (i&περίοδος;e&περίοδος; these are
individually selectable)&περίοδος; Both the forward protection and reverse protection are
operating at the same time&περίοδος; This is an additional protection feature
22&περίοδος;15 Cold load picks up(OPTIONAL)
Cold load pick-up allows for a loss of diversity when a load has been without supply
for a period&περίοδος;
Multiplier range&άνω κάτω τελεία; 1 – 5
Multiplier resolution&άνω κάτω τελεία; 0&περίοδος;1
Time Constant range&άνω κάτω τελεία; 1 – 480 min
Time constant resolution&άνω κάτω τελεία; 1 min
22&περίοδος;16 High impedance/conductor broken failure Optional
22&περίοδος;17 harmonic optional
22&περίοδος;18 Protection time-current curves&άνω κάτω τελεία; 1&περίοδος; IEC/IEEE &κόμμα;2&περίοδος;ANSI(OPETIONAL)
3&περίοδος;(optional Non Standard Inverse Time Curves)
IEC 60255 CURVES Inverse&κόμμα;Very Inverse and Extremely Inverse&περίοδος;
IEEE C37&περίοδος;122 Moderately Inverse&κόμμα;Very Inverse and Extremely Inverse&περίοδος;
22&περίοδος;19 Instantaneous protection
Instantaneous protection works by tripping the re-closer if the line current exceeds
the Instantaneous Multiplier x Setting Current&περίοδος;
Multiplier range&άνω κάτω τελεία; 1 – 30
Resolution of setting&άνω κάτω τελεία; 0&περίοδος;1
Max effective setting&άνω κάτω τελεία; 12&περίοδος;5kA
22&περίοδος;20 Definite time protection
Definite Time is an alternative to Inverse Time protection&περίοδος; It works by tripping the
Re-closer at a fixed time after pick-up&περίοδος;
Setting current range&άνω κάτω τελεία; 10 – 1260ΕΝΑ
Definite time resolution&άνω κάτω τελεία; 0&περίοδος;1 sec
Definite time range&άνω κάτω τελεία; 0&περίοδος;01 – 100 sec
Setting current resolution&άνω κάτω τελεία; 1ΕΝΑ
22&περίοδος;21 Sensitive Earth Fault (SEF) SEF trip Current Range&άνω κάτω τελεία; 5A-25A
MIN 5A(to Ground)/MIN25A(to phases)
SEF operating time range&άνω κάτω τελεία; 0&περίοδος;1-999sec
SEF trip current setting resolution&άνω κάτω τελεία; 1ΕΝΑ
SEF operating time resolution&άνω κάτω τελεία; 0&περίοδος;1S
22&περίοδος;22 Under / Over Voltage Protection
When selected&κόμμα; and a nominal Phase to Earth System operating voltage is set&κόμμα; the UOV Protection works within a defined threshold above and below the specified
voltage&περίοδος;
Under Voltage Lower Threshold Range&άνω κάτω τελεία;
50% – 88%
Over Voltage Upper Threshold Range&άνω κάτω τελεία; 112% – 150%
Trip After X Secs Range&άνω κάτω τελεία; 0 – 300 Seconds
Phase Logic
1&περίοδος;When ALL phases deviate beyond thresholds
2&περίοδος;When ANY phase voltage deviates beyond the thresholds
3&περίοδος;When the numerical AVERAGE of all phase Voltages deviates beyond the threshold&περίοδος;
22&περίοδος;23 Inrush restraint
Inrush restraint raises the phase and earth threshold currents for a short period of
time to allow for short duration inrush currents when closing onto a load&περίοδος;
Multiplier range&άνω κάτω τελεία; 1 – 30
Multiplier resolution&άνω κάτω τελεία; 0&περίοδος;1
Time range&άνω κάτω τελεία; 0&περίοδος;05 – 30 sec
Time resolution&άνω κάτω τελεία; 0&περίοδος;05 sec
23 MEASUREMENT FUNCTIONS
23&περίοδος;1 Voltage By phase&κόμμα;line and neutral
23&περίοδος;2 Current (0-1250ΕΝΑ) By phase &κόμμα;line and neutral
23&περίοδος;3 Power (Active and reactive) By phase and line
23&περίοδος;4 Energy (Active and reactive) By phase and line
23&περίοδος;5 Power factor By phase and line
22&περίοδος;6 Load profile registry (Amperage&κόμμα; voltage&κόμμα; power&κόμμα;energy power factor) 1&περίοδος;registry Every 15 minutes
2&περίοδος;Optional adjustable (0-60MIN)
24 ADDITIONAL FUNCTIONS&άνω κάτω τελεία;
24&περίοδος;1 Events Registrar 1&περίοδος;216 records of events
2&περίοδος;216 records of remote control
3&περίοδος;216 records of events of failure
4&περίοδος;45 records for fault waveform(15before and 30 after)
5&περίοδος;216 records of history events
24&περίοδος;2 The battery status monitor
24&περίοδος;3 Inputs and outputs programmable by the user
24&περίοδος;4 Native protocol Mod-bus/DNP3&περίοδος;0 profile
25 COMMUNICATION PORTS&άνω κάτω τελεία;
25&περίοδος;1 RS232 for Setting of communication protocols and Maintain of the control by PC
25&περίοδος;2 RJ45 for Setting&κόμμα; Program and Receiving of control BY PC
25&περίοδος;3 RS-232 for communication With DNP 3&περίοδος;0 /Mod-bus interface
25&περίοδος;4 RS-485 for communication With DNP 3&περίοδος;0 /Mod-bus interface
25&περίοδος;5 RJ45 for remote communication With DNP 3&περίοδος;0/IEC61850 standard interface
25&περίοδος;6 GRPS or Bluetooth or WI-FI or radio to connect with laptop
25&περίοδος;7 Unit with 1 or 2 Fiber optic port and 3 RJ45 Ethernet communication (option)
25&περίοδος;8 Protocol IEC60870-5-104/IEC69870-5-101 /DNP3&περίοδος;0/MODBUS/IEC61850(option)
25&περίοδος;9 COMMUNICATION BETWEEN RELAYS(OPTIONAL)
26 Supply voltage&άνω κάτω τελεία; 110/125/220/220VAC/DC(OPTIONAL)
27 Συχνότητα&άνω κάτω τελεία; 50Hz/60 Hz(OPTIONAL)
28 Back-up batteries&άνω κάτω τελεία; sealed free maintance &κόμμα;rechargeable in control box &κόμμα;monitor of power on diagnostic and continuous self monitoring 1&περίοδος;2AH/7AH/17AH/24AH(OPTIONAL)
2&περίοδος;2x12V=24VDC or 4x12v=48VDC
3&περίοδος;48hours with 20w if loss of power
29 Life years of recloser 10χρόνια
Life years of battery 5 χρόνια
30 Integrated battery charger/monitor is included
31 12VDC integrated auxiliary output to power a radio or moden another device for remote or local data transmission
32 Included of Heating resistors
33 Included of Control cable 15M and power cable from PT (option)
34 Included of Setting &κόμμα;Programming and Receiving software
35 Including of ac lamps and heaters of moisture contol
36 Including of electricnic magnetic lock for control box
37 Microprocessor realy in the front will be with IP20 to avoid of dust &κόμμα;insert &κόμμα;air contaminats &κόμμα;high humidity and vibration&περίοδος;
38 Main Protection Function Schematic