Beschreibung
Frequency Variable Three Phase AC Electric Motor VFD Inverted Duty 5~100Hz Squirrel Cage Induction Motors
———————————————————————————————
———————————————————————————————
Applications
Widely applied in metallurgy, chemistry, textile, pharmacy, printing, packing and food industry on the machine or equipment by which adjustable speed is needed, like fan, pump, numerical control machine, machining center, etc.
Widely applied in metallurgy, chemistry, textile, pharmacy, printing, packing and food industry on the machine or equipment by which adjustable speed is needed, like fan, pump, numerical control machine, machining center, etc.
General Description
- Frame sizes: 80 Zu 355
- Rated output: 0.18 to 375kW
- Insulation class: F
- Stromspannung: 380v
- Efficiency levels: IE1 / IE2 / IE3
- Frequency range for 2P: (3) 5-100Hz (frame size 80-250)
- (3) 5-70Hz (frame size 280)
(3) 5-60Hz (frame size 315-355) - Frequency range for 4, 6, 8, 10P: (3) 5-100Hz
Merkmale:
*Stepless speed regulation in a wide range
*Good performance, Energieeinsparung
*High-grade insulation material and special technological can withstand high frequency pulse impact
*Separated fan for forced-ventilation
*Separated fan for forced-ventilation
*Good performance, Energieeinsparung
*High-grade insulation material and special technological can withstand high frequency pulse impact
*Separated fan for forced-ventilation
*Separated fan for forced-ventilation
Optional Features:
Elektrisch:
Insulation Class:H
Thermal Protection: PTC Thermistor, Thermostat or PT100
Mechanical:
Others mountings
Protection Degree:IP55, IP56, IP65
Versiegelung:Lip seal, Oil seal
Space Heater
Drain Hole
Elektrisch:
Insulation Class:H
Thermal Protection: PTC Thermistor, Thermostat or PT100
Mechanical:
Others mountings
Protection Degree:IP55, IP56, IP65
Versiegelung:Lip seal, Oil seal
Space Heater
Drain Hole
Modell | Output kW |
Rated Ampere A | RPM | Eff.% | Power Factor | Rated Torque N.m |
dB(EIN) | Constant Torque Frequency Range Hz |
Constant Output Frequency Range Hz |
Synchronous speed 3000U/min | |||||||||
YE3VF80M1-2 | 0.75 | 1.7 | 2855 | 80.7 | 0.83 | 2.51 | 70 | 5-50 | 50-100 |
YE3VF80M2-2 | 1.1 | 2.4 | 2870 | 82.7 | 0.83 | 3.66 | 70 | ||
YE3VF90S-2 | 1.5 | 3.2 | 2865 | 84.2 | 0.84 | 5.00 | 74 | ||
YE3VF90L-2 | 2.2 | 4.6 | 2870 | 85.9 | 0.85 | 7.32 | 74 | ||
YE3VF100L-2 | 3 | 6.0 | 2875 | 87.1 | 0.87 | 9.97 | 78 | ||
YE3VF112M-2 | 4 | 7.8 | 2910 | 88.1 | 0.88 | 13.1 | 82 | ||
YE3VF132S1-2 | 5.5 | 10.6 | 2935 | 89.2 | 0.88 | 17.9 | 85 | ||
YE3VF132S2-2 | 7.5 | 14.4 | 2930 | 90.1 | 0.88 | 24.4 | 85 | ||
YE3VF160M1-2 | 11 | 20.6 | 2950 | 91.2 | 0.89 | 35.6 | 87 | ||
YE3VF160M2-2 | 15 | 27.9 | 2945 | 91.9 | 0.89 | 48.6 | 87 | ||
YE3VF160L-2 | 18.5 | 34.2 | 2945 | 92.4 | 0.89 | 60.0 | 87 | ||
YE3VF180M-2 | 22 | 40.5 | 2950 | 92.7 | 0.89 | 71.2 | 90 | ||
YE3VF200L1-2 | 30 | 54.9 | 2960 | 93.3 | 0.89 | 96.8 | 92 | ||
YE3VF200L2-2 | 37 | 67.4 | 2960 | 93.7 | 0.89 | 119 | 92 | ||
YE3VF225M-2 | 45 | 80.8 | 2965 | 94.0 | 0.90 | 145 | 94 | ||
YE3VF250M-2 | 55 | 98.5 | 2970 | 94.3 | 0.90 | 177 | 96 | 5-50 | 50-70 |
YE3VF280S-2 | 75 | 134 | 2975 | 94.7 | 0.90 | 241 | 98 | ||
YE3VF280M-2 | 90 | 160 | 2970 | 95.0 | 0.90 | 289 | 98 |
Modell | Output kW |
Rated Ampere A | RPM | Eff.% | Power Factor | Rated Torque N.m |
dB(EIN) | Constant Torque Frequency Range Hz |
Constant Output Frequency Range Hz |
Synchronous speed 3000U/min | |||||||||
YE3VF315S-2 | 110 | 195 | 2975 | 95.2 | 0.90 | 353 | 100 | 5-50 | 50-60 |
YE3VF315M-2 | 132 | 234 | 2975 | 95.4 | 0.90 | 424 | 100 | ||
YE3VF315L1-2 | 160 | 279 | 2975 | 95.6 | 0.91 | 514 | 100 | ||
YE3VF315L-2 | 185 | 323 | 2975 | 95.7 | 0.91 | 594 | 100 | ||
YE3VF315L2-2 | 200 | 349 | 2975 | 95.8 | 0.91 | 642 | 100 | ||
YE3VF315L3-2 | 220 | 383 | 2975 | 95.8 | 0.91 | 706 | 100 | ||
YE3VF355M1-2 | 220 | 383 | 2980 | 95.8 | 0.91 | 706 | 103 | ||
YE3VF355M-2 | 250 | 436 | 2980 | 95.8 | 0.91 | 801 | 103 | ||
YE3VF355L1-2 | 280 | 488 | 2980 | 95.8 | 0.91 | 897 | 103 | ||
YE3VF355L-2 | 315 | 549 | 2980 | 95.8 | 0.91 | 1009 | 103 | ||
YE3VF355L2-2 | 355 | 619 | 2980 | 95.8 | 0.91 | 1138 | 103 | ||
YE3VF355L3-2 | 375 | 654 | 2980 | 95.8 | 0.91 | 1202 | 103 | ||
Synchronous speed 1500U/min | |||||||||
YE3VF80M1-4 | 0.55 | 1.4 | 1430 | 80.6 | 0.75 | 3.67 | 62 | 5-50 | 50-100 |
YE3VF80M2-4 | 0.75 | 1.8 | 1425 | 82.5 | 0.75 | 5.03 | 62 | ||
YE3VF90S-4 | 1.1 | 2.6 | 1420 | 84.1 | 0.76 | 7.40 | 64 | ||
YE3VF90L-4 | 1.5 | 3.5 | 1420 | 85.3 | 0.77 | 10.1 | 64 | ||
YE3VF100L1-4 | 2.2 | 4.8 | 1430 | 86.7 | 0.81 | 14.7 | 68 | ||
YE3VF100L2-4 | 3 | 6.3 | 1430 | 87.7 | 0.82 | 20.0 | 68 | ||
YE3VF112M-4 | 4 | 8.4 | 1450 | 88.6 | 0.82 | 26.3 | 72 | ||
YE3VF132S-4 | 5.5 | 11.2 | 1465 | 89.6 | 0.83 | 35.9 | 76 | ||
YE3VF132M-4 | 7.5 | 15.0 | 1465 | 90.4 | 0.84 | 48.9 | 76 | ||
YE3VF160M-4 | 11 | 21.5 | 1470 | 91.4 | 0.85 | 71.5 | 79 | ||
YE3VF160L-4 | 15 | 28.8 | 1470 | 92.1 | 0.86 | 97.4 | 79 | ||
YE3VF180M-4 | 18.5 | 35.3 | 1470 | 92.6 | 0.86 | 120 | 83 | ||
YE3VF180L-4 | 22 | 41.8 | 1465 | 93.0 | 0.86 | 143 | 83 | ||
YE3VF200L-4 | 30 | 56.6 | 1475 | 93.6 | 0.86 | 194 | 85 | ||
YE3VF225S-4 | 37 | 69.6 | 1480 | 93.9 | 0.86 | 239 | 88 | ||
YE3VF225M-4 | 45 | 84.4 | 1480 | 94.2 | 0.86 | 290 | 88 | ||
YE3VF250M-4 | 55 | 103 | 1485 | 94.6 | 0.86 | 354 | 92 | ||
YE3VF280S-4 | 75 | 136 | 1490 | 95.0 | 0.88 | 481 | 94 | ||
YE3VF280M-4 | 90 | 163 | 1485 | 95.2 | 0.88 | 579 | 94 | ||
YE3VF315S-4 | 110 | 197 | 1485 | 95.4 | 0.89 | 707 | 96 | 50-75 | |
YE3VF315M-4 | 132 | 236 | 1485 | 95.6 | 0.89 | 849 | 96 | ||
YE3VF315L1-4 | 160 | 282 | 1485 | 95.8 | 0.90 | 1029 | 96 | ||
YE3VF315L-4 | 185 | 326 | 1485 | 95.9 | 0.90 | 1190 | 96 | ||
YE3VF315L2-4 | 200 | 352 | 1485 | 96.0 | 0.90 | 1286 | 96 |
Specifications of cooling blower and brake for the motor
Motor | Frame | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 |
Cooling Fan | (W) Leistung |
30 | 42 | 52 | 55 | 55 | 80 | 80 | 150 | 200 | 230 | 320 | 700 | 700 |
(EIN) Aktuell |
0.09 | 0.16 | 0.18 | 0.18 | 0.19 | 0.26 | 0.30 | 0.6 | 0.6 | 0.6 | 1.1 | 1.8 | 1.9 | |
Stromspannung | Standard 380V, but blower of other voltage can be customized depending on user’s requirement. | |||||||||||||
Encoder Optional | Incremental Encoder |
Mounting Type:
Conventional mounting type and suitable frame size are given in following table(with “√“)
Frame | basic type | derived type |
|||||||||||||
B3 | B5 | B35 | V1 | V3 | V5 | V6 | B6 | B7 | B8 | V15 | V36 | B14 | B34 | V18 | |
80~112 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
132~160 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | – | – | – |
180~280 | √ | √ | √ | √ | – | – | – | – | – | – | – | – | – | – | – |
315~355 | √ | – | √ | √ | – | – | – | – | – | – | – | – | – | – | – |
If there is no other request in the order or agreement, terminal box standard position is at the right side of the frame; data above may be changed without prior notice.
Site
Show Room
Premium Service
Zertifikate
Quality Control
Wannan Motor Production Workshop and Flow Chart
Hundreds of Certificates, Honors and more COMPANY information please go to “ABOUT US”
—————————————————————————————————————————
Welcome to contact us directly…
wnmmotor.en.made-in-china.com
https://youtu.be/frVvg3yQqNM
WANNAN MOTOR INDUSTRIAL SOLUTIONS