Produktionskapacitet
1000K

Beskrivelse

Split core CT with UL2808,UL.CE,UKCA

SPLIT CORE CURRENT TRANSFORMERS

The SCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The SCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.

Funktioner:
1:The structure of the self-locking, safe, easy to install, portable
2:Wide inner window, allowing clamping of big cables or bus-bars
3:Wide range of sizes to accommodate all the existing installations
4:Isolated plastic case recognized according to UL94-V0
5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs


Ansøgninger:
1:Current measurement, monitoring and protection for electrical wiring and equipment.
2:Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition equipment and automationcontrol system.
3:Strøm, power and energy monitoring device.

4:Relay protection device.

Technique Index:

Electrical Parameter Mechanical Parameter
Frequency 50-2KHz Case PA/UL94-V0
Rated Input 5A-200A Bobbin PBT
Measuring range 10%In-120%In Core Silicon steel
Rated Output 0.333V(AC)or 0-500mA Internal structure Epoxy
Ratio ≤ ± 1.0% Construction Tie
Phase angle ≤ ±60min Operation Temp -25oC~+75oC
Dielectric strangth 2.5KV/1mA/1min Operating Humidity ≤85%
Isoleringsmodstand DC500V/100MΩ min Output Connection UL1015 20AWG Wire2.5m




Accuracy class characteristics:

Specifikation:

PCT-T06

Split Core Current Transformer with Ukca, UL, CE

MODEL PCT-6
Current Ratio 5A/2.5mA 10A/5mA 20A/10mA
Primary Current 5EN 10EN 20EN
Max.Current 30EN 30EN 300EN
Produktion 2.5mA 5mA 10mA
Load Resistance 200Ω 100Ω 50Ω
Class 0.5/1.0
Turns Ratio 2000:1 2000:1 2000:1
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installable
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T10

Split Core Current Transformer with Ukca, UL, CE

MODEL PCT-10
Current Ratio 5A/2.5mA 20A/10mA 60A/20mA 75A/25mA 1~75A/0.333V
Primary Current 5EN 20EN 60EN 75EN 1~75A
Max.Current 60EN 60EN 750EN 75EN 1~75A
Produktion 2.5mA 10mA 20mA 25mA 333mV
Load Resistance 400Ω 100Ω 50Ω 20Ω /
Class 0.5/1.0
Turns Ratio 2000:1 2000:1 3000:1 3000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installable
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T16

Split Core Current Transformer with Ukca, UL, CE

MODEL PCT-16
Current Ratio 100A/33.3mA 100A/40mA 120A/40mA 200A/66.7mA 100~200A/0.333V
Primary Current 100EN 100EN 120EN 200EN 100~200A
Max.Current 120EN 120EN 120EN 240EN 240EN
Produktion 33.3mA 40mA 40mA 66.7mA 333mV
Load Resistance 50Ω /
Class 0.5/1.0
Turns Ratio 3000:1 2500:1 3000:1 3000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installable
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T24

Split Core Current Transformer with Ukca, UL, CE

MODEL PCT-24
Current Ratio 100A/40mA 200A/40mA 200A/66.7mA 400A/80mA 100~400A/0.333V
Primary Current 100EN 200EN 200EN 400EN 100~400A
Max.Current 150EN 240EN 240EN 480EN 4800EN
Produktion 40mA 40mA 66.7mA 80mA 333mV
Load Resistance 50Ω /
Class 0.5/1.0
Turns Ratio 2500:1 5000:1 3000:1 5000:1 /
Protection Level 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installable
Storage Condition -30ºC~+50ºC,≤85%RH,No condensation

PCT-T36

Split Core Current Transformer with Ukca, UL, CE

MODEL PCT-36
Current Ratio 300A/100mA-5a
Primary Current 300EN
Max.Current 360EN
Produktion 100mA-5a
Load Resistance 50Ω
Class 0.5/1.0
Turns Ratio 3000:1
Protection Level 7.5V0-P
Insulation Category CATIII
Operating Condition -20ºC~+50ºC,≤85%RH,No condensation,IN-house&Any direction installable