وصف
LY1000GH-W High Concentration Gas High Voltage Genset Technical Parameters 50Hz
NOX≤500mg/Nm³1)
Minimum Low Heating Value (LHV) Min: 3.0 KWh/Nm³
NOX≤500mg/Nm³1)
Minimum Low Heating Value (LHV) Min: 3.0 KWh/Nm³
Engine Model | LY12V170-W | ||
Engine power2) | كيلوواط | 1035 | |
Rated rotation speed | دورة في الدقيقة | 1500 | |
Average effective pressure | MPa | 1.58 | |
Exhaust gas temperature | درجة مئوية | ≤550 | |
Wet exhaust flow | حول | kg/h | 5448 |
Combustion air flow | ±8% | kg/h | 4805 |
Inlet air temp after intercooling | ±5 | درجة مئوية | 50 |
Ventilation volume3) | حول | kg/h | 29015 |
Engine Technical Parameters | |||
Bore/Stroke | مم | 170/195 | |
Displacement | dm3 | 53.1 | |
Average piston speed | m/s | 9.75 | |
Lubricant capacity4) | dm3 | 180 | |
Lubricant consumption rate with 100% حمولة | g/kWh | ≤0.4 | |
المولد | |||
كفاءة5) | % | 96.6 | |
Energy Balance | LY1000GH-W | ||
Output electric power5) | كيلوواط | 1000 | |
High temp coolant heat | ±8% | كيلوواط | 598 |
Low temp coolant heat | ±8% | كيلوواط | 98 |
Heat of exhaust gas cooled to 120 درجة مئوية | ±8% | كيلوواط | 572 |
Radiated heat from the engine | حول | كيلوواط | 43 |
Radiated heat from the alternator | حول | كيلوواط | 34 |
Gas consumption | ±5% | كيلوواط | 2531 |
Electrical efficiency | % | 39.5 | |
Thermal efficiency | % | 46.2 | |
Total efficiency | % | 85.7 | |
System Parameters | |||
Min/Max flow of high temp coolant | م3/ح | 40/56 | |
Engine Kvs value6) | م3/ح | 42 | |
Flow of low temperature coolant | م3/ح | 35 | |
Intercooler Kvs value6) | م3/ح | 30 | |
Engine coolant capacity | dm3 | 111 | |
Intercooler coolant capacity | dm3 | 28 | |
High temp coolant temperature inlet/outlet | درجة مئوية | 78/92 | |
Low temp coolant temperature inlet/outlet | درجة مئوية | 48/52 | |
الأعلى exhaust back pressure | كيلو باسكال | 5 | |
Max pressure drop before the air filter | كيلو باسكال | 0.5 | |
Gas pressure range | كيلو باسكال | 3-20 | |
Startup method and battery capacity | Electric startup & [البريد الإلكتروني محمي] |
1) Exhaust gas emission: Oxygen content 5%, dry exhaust gas, NOx≤500mg/Nm3
2) Engine power rating is based on ISO 3046/1 standard
3) The amount of ventilation air at Delta T=15K, including the amount of combustion air
4) Piping and lubricant heat exchangers are excluded
5) Frequency 50Hz, voltage 10500V, power factor is 1.0
6) The Kvs value refers to the flow rate with a pressure loss of 1 bar
This data is for reference only and is not intended to be a binding value. Please refer to the information in the technical agreement.
Genset نموذج | LY1100GH-W | |||||||||||||
Dimensions | ||||||||||||||
طول | حول | مم | 5300 | |||||||||||
Width | حول | مم | 1700 | |||||||||||
ارتفاع | حول | مم | 2300 | |||||||||||
Net weight | حول | كلغ | 13000 | |||||||||||
ضوضاء | ||||||||||||||
Sound power level | Multiplier | هرتز | 32 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||
Exhaust noise | 120 | ديسيبل (أ) | 109 | 115 | 122 | 121 | 118 | 110 | 109 | 107 | 106 | |||
Unit noise | 103 | ديسيبل (أ) | 96 | 101 | 95 | 96 | 96 | 97 | 96 | 95 | 97 | |||
Exhaust gas noise at 1 meter, ±2.5 dB (أ)
Unit side noise at 1 meter, ±1 dB (أ)