وصف
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.
50Hz Diesel Gneerator Series powered by Cummins |
|||||||||
Generator Set Performance | Engine Specification | Soundproof type | |||||||
Genset Model | 50Hz Output | Engine Model | قوة(Kw) | Fuel Comsuption(100% Load) | البعد | وزن | |||
50هرتز | Prime | Standby | كيلوواط | L/H | L*W*H(مم) | كجم | |||
KVA | كيلوواط | KVA | كيلوواط | ||||||
GF/GFS-C250 | 250 | 200 | 275 | 220 | NT855-GA | 231 | 42.7 | 3500*1300*2000 | 3300 |
زF/زFS-C275 | 275 | 220 | 312.5 | 250 | NTA855-G1A | 261 | 60.44 | 3500*1300*2000 | 3500 |
زF/زFS-C313 | 313 | 250 | 344 | 275 | NTA855-G1B | 284 | 61.18 | 3500*1300*2000 | 3500 |
زF/زFS-C344 | 344 | 275 | 375 | 300 | NTA855-G2A | 313 | 64 | 3500*1300*2000 | 3700 |
زF/زFS-C350 | 350 | 280 | 387.5 | 310 | NTA855-G4 | 318 | 65 | 3500*1300*2000 | 3900 |
زF/زFS-C375 | 375 | 300 | 412.5 | 330 | NTAA855-G7 | 343 | 69.9 | 3500*1300*2000 | 3900 |
زF/زFS-C409 | 450 | 360 | NTAA855-G7A | 377 | 76.89 | 3500*1300*2000 | 4150 | ||
زF/زFS-C450 | 450 | 360 | 500 | 400 | KTA19-G3 | 403 | 83.9 | 3800*1400*2100 | 5200 |
زF/زFS-C500 | 500 | 400 | 550 | 440 | KTA19-G3A | 448 | 90 | 4200*1400*2200 | 5400 |
زF/زFS-C525 | 525 | 420 | 631.2 | 505 | KTAA19-G5 | 470 | 97.9 | 4500*1400*2200 | 5900 |
زF/زFS-C575 | 575 | 460 | 650 | 520 | KTAAA19-G6 | 520 | 107.2 | 4500*1400*2200 | 5900 |
زF/زFS-C625 | 687.5 | 550 | KTAA19-G6A | 560 | 116.5 | 4500*1400*2200 | 5900 | ||
زF/زFS-C590 | 650 | 520 | KTA19-G8 | 575 | 116.5 | 4500*1400*2200 | 5900 | ||
زF/زFS-C614 | 675 | 540 | KTA38-GA | 560 | 130 | 5500*2000*2900 | 8000 | ||
زF/زFS-C625 | 625 | 500 | 687.5 | 550 | KTA38-G | 560 | 116.5 | 5500*2000*2900 | 8000 |
زF/زFS-C750 | 750 | 600 | 825 | 660 | KTA38-G2 | 664 | 139.8 | 5500*2000*2900 | 8200 |
زF/زFS-C800 | 800 | 640 | 887.5 | 710 | KTA38-G2B | 711 | 170 | 5500*2000*2900 | 8500 |
زF/زFS-C910 | 910 | 728 | 1001 | 800 | KTA38-G2A | 813 | 170 | 5500*2000*2900 | 8500 |
زF/زFS-C1000 | 1000 | 800 | 1100 | 880 | KTA38-G5 | 880 | 186.4 | 5800*2140*3080 | 9500 |
——————————– —————————————————–After-Sale Part————————————————————————————
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | عادة,it is caused by lack of Water or Oil Shortage,or Overload. —-Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | عادة,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.—– When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | عادة,it caused by lacking of Water or Oil Shortage,or Overload.—–When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.—The light in on at the initial Start,when the charger reaches a certain speed,the light is off.—This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |
Welcome your sending inquiry and directly contact!