Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

نموذج رقم.
MD0630T41A

حسب الطلب
حسب الطلب

اسم المنتج
6mA DC 30mA AC Residual Current Detector Sensor

حاضِر
DC Current 2~15mA, AC Current 3~100mA

تثبيت
Cable & Pin Type

3 Ways Output
DC Alarm, AC Alarm, AC/DC Alarm

شهادة
TUV-IEC, CE-EMC

الاستخدام
Leakage/Residual Current Protection

الجهد االكهربى
12الخامس

Theory
Current Sensor

دقة
DC 0.2mA, AC 0.3mA

حزمة النقل
كرتون

تخصيص
TBA

علامة تجارية
IVY

أصل
تشجيانغ, الصين

رمز النظام المنسق
8536411000

السعة الإنتاجية
5, 000, 000.00/ سنة

وصف

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor

الجهد االكهربى 12V±20%
حاضِر DC current 2~15mA, AC current 3~100mA
دقة DC±0.2mA, AC±0.3mA @ 25درجة مئوية
3 Wayق الإخراج DC alarm, AC alarm, AC/DC alarm
Operation Temperature Range -25~+80درجة مئوية
تثبيت Cable & Pin اكتب
Plastic Casing SIP encapsulation

Evse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD SensorEvse Solution 6mA DC 30mA AC Leakage Current Monitoring RCD Sensor
Caution of Leakage Sensor:

MD0630T41A is a high sensititivity AC DC leakage current sensor for electric vehice charging station,
which can also be called residual current sensor, residual current monitor (RCM), residual current device
(RCD), differential current sensor, leakage detection sensor, fault current sensor etc.

To satisfy new standards including IEC 62955,IEC 62752, IEC 61851-1,and UL 2231-1 إلخ, the charging
of electric vehicles requires leakage current sensors to avoid hazardous situations in cases where the
vehicle battery(DC) is connected to the home power supply(تكييف).

Generally, AC DC Sensitive residual current sensors can be used where DC and AC circuits are directly
connected and therefore AC DC leakage currents occur. our MD series leakage sensor would be required
to guarantee safety in the event of DC fault current. Used in Mode 2 and Mode 3 EV Charging.

This residual current sensor will detect DC and AC leakage currents in 50Hz/60Hz AC installations according
to IEC62955. It’s intended for use in Electric Vehicle charging stations, جomplies with the DC protection requirements
of IEC62955.
It will protect against DC (6أماه) and AC (30أماه) residual currents, and will signal to the Smart EVSE