48VDC/110DC/220VDC Thyristor Rectifier DC Battery Charger with Ni-CD Battery Bank

نموذج رقم.
GZDT

بحجم
أ

شهادة
هذه

Socket Type
Southamerica

Recyclable
Non-Recyclable

حزمة النقل
Wooden

تخصيص
30VDC/48VDC/110VDC/220VDC

علامة تجارية
HEMG

أصل
الصين

السعة الإنتاجية
5000set/Year

وصف

7.10 Technical Particulars & Guarantees of
110V DC Sub-Station Battery

إس إل. لا. وصف وحدة BPDB’s Requirement Manufacturers Guaranteed Particulars
1 Manufacturers name & country To be mentioned HEMG/CHINA
2 Manufacturers model no. To be mentioned GNZ100
3 اكتب Nickel Cadmium Alkaline (enclosed type) Nickel cadmium Alkaline(open type)
4 Operating Voltage V DC 110 110
5 Continuous Discharge Current at rate of 10 hour & Final Cell Voltage 1.1 Volt أمبير 10 10أ
6 Short Time Discharge Current at rate of 2 hour & Final Cell Voltage 1.1 Volt أمبير 50 50أ
7 Electrolyte type To be mentioned Alkaline solutions
8 Capacity at 10 hour rate AH 100 100اه
9 Discharge Voltage Volt 1.3 Per Cell 1.3 Per Cell
10 Charging Voltage (Normal) Volt 1.6 Per Cell 1.6 Per Cell
11 Number of cells Nos. 92 nos. +5nos. Spare 92 nos.+5 nos. Spare
12 Voltage per cell الخامس 1.2 1.2الخامس
13 Charging Voltage (Maximum) Volt 1.75 Per Cell 1.75 Per cell
14 Normal float charge rate أ To be mentioned 0.2أ-0.3أ
15 Maximum boost charge rate أ To be mentioned 30أ
16 Amp hour efficiency at:
أ) 10 hour rate
b) 1 hour rate

%
%

To be mentioned
To be mentioned
108%
60%
17 Size of cell Mm To be mentioned 165*105*345مم(ABS or PP container)
18 Weight of cell and electrolyte كجم To be mentioned 9.3كجم/1.70كجم
19 Standard As per Latest Edition of applicable IEC-60623 IEC-60623
20 Specific gravity of electrolyte To be mentioned 1.20±0.02ز/cm3
21 Release pressure for valve regulated type كجم/m2 To be mentioned 0.005×10-4Kg/m2
22 Volume of electrolyte per cell Ml To be mentioned 1.8ل
23 Volume of reserve electrolyte per cell Ml To be mentioned 0.78ل
24 No of electrode plates per cell Nos. To be mentioned Positive 12 جهاز كمبيوتر شخصى
Negative 11 جهاز كمبيوتر شخصى
25 Type of racks
أ) ارتفاع
b) Width
ج) Depth


To be mentioned
Steel
3360
640
626
26 Cell dimension:
أ) ارتفاع
b) Width
ج) Depth

To be mentioned

165
105
345
27 Rack Dimensions
أ) ارتفاع
b) Width
ج) Depth

3360
640
626
28 Recycling facilities for unserviceable batteries available or not ي/N To be mentioned لا


Seal & Signature of the Manufacturer Seal & Signature of the Bidder

7.11 Technical Particulars & Guarantees of Sub-Station
110V DC Battery Charger

إس إل. لا. وصف وحدة BPDB’s Requirement Manufacturers Guaranteed Particulars
1 Manufacturers name & country To be mentioned HEMG
2 Manufacturers model no. To be mentioned GZDT-110V/50أ
3 Rating To be mentioned 10KVA
4 Rated Input voltage range فولت تيار متردد 415 الخامس ± 10% 415الخامس±10%
5 Rated Frequency هرتز 50 هرتز (±3%) 50هرتز±3%
6 No of Phase 03 03
7 Control Shall be mentioned PLC+Touch screen
8 Communication module for station automation Shall be provided 485
9 Rectifier type Silicon Silicon
10 Nominal output voltage V DC 110 110الخامس
11 Charging operating control Boost and floating charge, automatic with manual operation manual operation
12 Output current A DC ≥ 40 50أ
13 Continuous current rating 110% of rated current 110% of rated current
14 كفاءة % ≥ 85 ≥85%
15 Voltage regulation % ± 0.5 ≥±0.5%
16 Ripple voltage mV ≥ 150 ≤150
17 Boost charging voltage الخامس/cell 1.6 to 1.75 (programmable) programmble
18 Boost charging time Hour Programmable programmable
19 درجة حرارة التشغيل °C 0 ل 50 0~50
20 رطوبة % 95 95%
21 Audible noise ديسيبل ≥ 65 ≤65
22 Facilities for paralleling with another charger Shall be provided One charger
23 Protection against surge voltage Shall be provided Surge arrester
24 Protection against reverse polarity Isolation diodes
25 Provision for current limiting 110%
26 Provision of constant voltage charge 90V -130V 80-160الخامس
27 Provision of showing earth leakage current by analog meter 20أماه
28 Battery Temperature compensation Shall be incorporated. -2~3mv/درجة مئوية(20درجة مئوية)
29 Alarm annunciator independent of the microprocessor Shall be provided PLC
30 Analog meters for voltage and current measurement of input output and battery power
Shall be mentioned
Dc voltmeter
Dc current meter
31 البعد Shall be mentioned 800×600×2260mm
32 Output voltage range
أ) Normal charge
b) Float charge
ج) Boost charge

V DC
V DC
V DC

110 الخامس ± 1%
120 الخامس ± 1%
150 الخامس ± 1%

110 الخامس ± 1%
120 الخامس ± 1%
150 الخامس ± 1%
33 Normal/boost charge independent units? نعم/لا To be mentioned لا
34 Output current أ 50 50
35 Rated Battery Current أ 20 20
36 كفاءة % To be mentioned 80%
37 Ripple Voltage % 3% 3%
38 Type of AVR Static 20الخامس
39 Installation Break Down Voltage KV 2KV for 1 Minute 2KV for 1 Minute
40 Type of rectifier Thyristor To be mentioned Thyristor
41 MCCB
أ) Quantity Nos. MCB will be provided near AC input & DC Output Meet customer needs
b) Rating أ AC input MCB-50A DC Output MCB-63A AC input MCB-50A DC Output MCB-63A
42 Standard As per Latest Edition of Applicable IEC-60146 IEC-60146